CLEAN ENVIRONMENT ENGINEERS, INC. <br /> WATER PUMP WITH ELECTRO--ENEUMATIC INTERFACE <br /> When a high volume of water must be removed to create a cone of depression, it <br />' can become cost effective to use an electric submersible pump. Such a pump can <br /> be added to an SOS spill recovery system by using the SOS Electro-Pneumatic <br /> Interface. The module is suitable to be used in Division 1, Class 11 <br />' locations. It connects to an SOS pneumatic recovery system via simple quick <br /> disconnects. <br /> There are no electric sensors down the well. The water level in the well is <br /> monitored by the pneumatic bubbler system,. When the water level rises above the <br /> bubbler hole in the SOS skimmer, the Electro-Pneumatic Interface turns on the <br />' electric pump. When the water is drawn down, the pump is shut down. The "On <br /> Level" and "Off Level" can be adjusted to accommodate removal rates. Such an <br /> adjustment allows for longer "on" times for the pump and fewer starts. This <br /> prolongs the life of the electric pump. <br /> The electric pump supplied by CEE is stainless steel and available from 113 to 5 <br /> horsepower. Bonded teflon seals are used in the pumps which reduce start-up and <br /> operating current. This saves in operating costs and means longer pump <br /> life. They will operate in wells as small as 4-inch inside diameter. <br /> For added safety, the electrical wires are encased in a polyurethane <br /> tube to prevent nicking during handling or installation. <br /> 1 <br /> I <br /> I <br /> I . <br /> M <br />