u <br /> April 22, 1987 AGS 8691-6 <br /> Beacon Service Station #1-502 - Lodi, California <br /> Applied GeoSystems recommends that the ground water contamination <br /> be mitigated by withdrawal and discharge to the sanitary sewer <br /> system. Soil contamination should be mitigated through <br /> installation and operation of a soil . venting system, using wells <br /> completed in the vadose zone and installed within the tank <br /> cavity. Operation of a soil leaching system may tend to increase <br /> the levels of contamination present in the ground water, <br /> inhibiting the effects of the ground water mitigation program. <br /> Copies of this report should be forwarded to Laurie Cotulla, of <br /> the San Joaquin Local Health District, and to Stephen Boll, of <br /> the Central Valley Region of the California Regional water <br /> Quality Control board. Please do not hesitate to call if you <br /> should have any questions regarding this report or any other <br /> aspect of this project. <br /> LIMITATIONS <br /> This report was prepared in accordance with generally accepted <br /> standards of environmental geological practice in California at <br /> the time this investigation was performed. This investigation <br /> was conducted solely for the purposes of evaluating environmental <br /> conditions of the soil with respect ' to hydrocarbon product <br /> contamination in the vicinity of the removed tank. No soil <br /> 12 <br /> .4,�,o/ied GeoSystems <br />