EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2900 - Site Mitigation Program
>
PR0543467
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 4:18:47 PM
Creation date
5/20/2019 9:20:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0543467
PE
2960
FACILITY_ID
FA0024672
FACILITY_NAME
FORMER ATLANTIC RICHFIELD CO (ARCO) NO 6100
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS
P_LOCATION
03
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SJVAPCD September 12,2003 <br /> Authority to Construct/Permit to Operate <br /> Page 2 <br /> SOIL VAPOR EXTRACTION AND ABATEMENT <br /> The King, Buck/Hasstech, 200 scfm catalytic oxidizer units incorporate a 7.5 hp blower <br /> each (rated at 200 scfm maximum @ 4" Hg) to extract petroleum laden soil vapors from <br /> wells VW-1, VW-3, VW-4, VW-6, VW-7, VW-8, VW-11, VW-12, VW-13, VW-14, <br /> VW-16, and MW-2 through MW-9 (Figure 2). The proposed oxidizer units have similar <br /> configuration with exceptions of electrical requirements and manufacturer of blower. <br /> The oxidizer with serial number 9230 operates under single phase electrical requirements <br /> with a Tuthill blower while the other oxidizer with serial number 9321 operates under <br /> three-phase electrical requirements with a Sutorbilt 4M blower. The SVE systems will be <br /> operated under catalytic mode to treat the soil vapors prior to discharge to the <br /> atmosphere. A process flow diagram illustrating the operation of these two units is <br /> presented in Figure 3. Equipment specifications are presented in Appendix B. Pertinent <br /> equipment specifications for both the units are listed below: <br /> Parameter Oxidizer with Sl. No. 9230 Oxidizer with SI. No 9321 <br /> Blower Make Tuthill Sutorbilt 4M <br /> Blower Capacity 200 cfm 200 cfm <br /> Electrical Requirement Single Phase, 7.5 hp Three Phase, 7.5 hp <br /> Stack Height 10 feet above ground 10 feet above ground <br /> surface surface <br /> Stack Inner Diameter 5-inches (circular) 5-inches (circular) <br /> Destruction Efficiency 95 —98 percent 95—98 percent <br /> Distance to Nearest Approximately 20 feet Approximately 20 feet <br /> Station Building <br /> Height of Nearest Station Approximately 12 feet Approximately 12 feet <br /> Building <br /> A soil vapor extraction pilot test was conducted at the site in October 1991 extracting soil <br /> vapors from wells VW-1 through VW-4. During the test, influent total petroleum <br /> hydrocarbons as gasoline (TPHG) concentrations ranged from 130,000 milligrams per <br /> cubic meter (mg/m3) to 160,000 mg/m3' A radius of influence of 35 feet was estimated <br /> during this test. <br /> PABA-Arco for URS\6100\C=espondwce\Arco 6100 ATC appticationAm <br />
The URL can be used to link to this page
Your browser does not support the video tag.