GROUNDWATER TECHNOLOGY, INC. <br /> STANDARD OPERATING PROCEDURE NO. 8 <br /> GROUNDWATER MONITORING <br /> Groundwater monitoring of wells at the site shall be conducted using an ORS Environmental <br /> Equipment (ORS) INTERFACE PROBE' or SURFACE SAMPLER' The INTERFACE PROBE' is a <br /> hand-held, battery-operated device for measuring depth to petroleum product and depth to <br /> water as measured from an established datum 0 e , top of the well casing which has been <br /> U <br /> surveyed) Floating separate-phase hydrocarbon (product) thickness is then calculated by <br /> subtracting the depth to product from the depth to water In addition, water elevations are <br /> adjusted for the presence of floating product with the following calculation: <br /> (Product Thickness) x (0.8) + (Water Elevation) = Corrected Water Elevation <br /> Note- The factor of 0 8 accounts for the density difference between water and <br /> petroleum hydrocarbons <br /> The thickness of dense non-aqueous phase liquids (DNAPLs) is calculated by subtracting the <br /> depth at which the DNAPL is encountered from the total depth of the well. Water-level <br /> elevations are not typically corrected for the presence of DNAPLs. <br />) � The INTERFACE PROBE' consists of adual-sensing probe which utilizes an optical liquid sensor <br /> and electrical conductivity to distinguish between water and petroleum products. A coated <br /> steel measuring tape transmits the sensor's signals to the reel assembly where an audible alarm <br /> sounds a continuous tone when the sensor is immersed in petroleum product and an oscillating <br /> tone when immersed in water The INTERFACE PR08ETM is accurate to 0.01 inch <br /> A SURFACE SAMPLER' shall be used for visual inspection of the groundwater to note sheens <br /> (difficult to detect with the INTERFACE PROBE'"), odors, microbial action, etc. <br /> The SURFACE SAMPLER' used consists of a 12-inch-long case acrylic tube with a Detnn ball <br /> which closes onto a conical surface creating a seal as the sampler is pulled up The sampler is <br /> calibrated in inches and centimeters for visual inspection of product thickness <br /> 1 To reduce the potential for cross contamination between wells, the monitoring shall take place <br /> in order from the least to the most contaminated welts Wells containing separate-phase <br /> hydrocarbons (free product) should be monitored last. Between each monitoring the equipment <br /> shall be washed with laboratory-grade detergent and double rinsed with distilled water <br /> , <br /> 1 <br /> CONCOPM SOP 121841 <br /> �i—I&I GROUNDWATER <br /> �; TECHNOLOGY, INC. <br />