F 22 <br /> VGT <br /> a xylem brand Issued: 2/96 Supersedes: 6/90 <br /> Storage <br /> Each Flygt pump leaves the factory properly assembled CONTROLS: <br /> and prepaired to perform even after a reasonable idle <br /> time in storage.However,as prolonged idle time can be It is most important to make sure that Electrical <br /> detrimental to any rotating machinery, the procedures Controls, when subjected to extended storage, be <br /> outlined below should be followed in order to insure stored in a protected dry environment free from any <br /> that the equipment is in top condition to operate when corrosive atmosphere. Moisture in any form, including <br /> finally installed.Whenever possible,store pumping units condensation, can cause serious corrosion problems to <br /> in a dry environment free of extreme temperatures and the contact pointsurfaces as well asterminal connections. <br /> strong direct sunlight. <br /> Even though all terminal connections have been made <br /> NEW pumps: tight on initial assembly atthe factory,they may not remain <br /> 100% tight over an extended storage period due to the <br /> Storage 6t 12 months: compressibility of the copper wire and possible movement <br /> In general, rotating machinery left idle for extended due to variations in ambient temperature. The problem <br /> periods of time, tends to establish a "set" position due will vary in degree depending on wire size and whether <br /> to inaction of the moving parts. Some of these areas the terminal connection is of solid or stranded wire. To <br /> may be damaged (especially seals) from the sudden insure proper operation, recheck all terminal connection <br /> fast breakaway of start-up after a prolonged idletime.To screws for tightness prior to placing the control on line. <br /> insure that all rotating parts are free for final installation <br /> and start-up, it is good practice to rotate the impeller by <br /> hand once a month. It is also good practice to relieve <br /> the tension on the cable entry sealing grommet by <br /> backing off the cable entry compression screws slightly. <br /> If this is done, it is most important that a clear note be <br /> attached as a reminder to: <br /> Re-Tighten Cable Entry Compression Screws Before <br /> Installation. <br /> Storage 12 to 24 months: <br /> In addition to the above,apply a protective spray coating <br /> of silicone or rust inhibiting oil to the impeller and inside <br /> of the volute by spraying in through the volute outlet <br /> and up through the volute inlet. Also coat the volute <br /> outlet flange face. <br /> USED pumps: <br /> Before storing a used pump for an extended period of <br /> time, the unit should be dismantled, checked for any <br /> defects,repaired where necessary and reassembled.At <br /> reassembly,follow instructions in the Service Manual, <br /> especially regarding seal assemblies. Protect the <br /> impeller and volute as mentioned in the paragraph above. <br /> In all cases,itis good practice to check all external bolts, <br /> nuts and screws for tightness before final installation <br /> after extended storage. <br />