My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
B
>
1604
>
2800 - Aboveground Petroleum Storage Program
>
PR0515766
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2019 8:48:47 AM
Creation date
5/24/2019 1:55:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515766
PE
2832
FACILITY_ID
FA0003683
FACILITY_NAME
Caltrans-Stockton
STREET_NUMBER
1604
Direction
S
STREET_NAME
B
STREET_TYPE
St
City
Stockton
Zip
95206
APN
171-090-08
CURRENT_STATUS
01
SITE_LOCATION
1604 S B St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Emergency Shut Off <br /> The Emergency Shut Off switch for the 6000 gal. ConVault hank is located at the rear of the tank on the <br /> security fence within 15 feet of the AST systems, but not less than 25 feet from the fuel dispenser. <br /> Emergency Shut Off switch is located on the Nordleast fence of the fueling operations by the building <br /> which is contiguous to the fueling operations,and is at approximately eye level. <br /> Secondary Containment <br /> ConVault Tank: The 6000 Gallon ConVault Aboveground Storage Tank has integral secondary <br /> containment. As part of its listing from Underwriter's Laboratories, Standard UL 2085 <br /> Protected Tanks listing, the system is a primary steel tank vessel which is then surrounded by a <br /> concrete envelope and in between steel and concrete there is a space also known as the <br /> interstice. As this tank has both the primary containment and the secondary containment in one <br /> system, the secondary containment is determined to be "integral secondary containment." The <br /> Underwriter's Laboratories"Nameplate" confirms this information. <br /> Oman Cummins Tank: The 79 Gallon fuel tank for the Onan Cummins Generator System has <br /> integral secondary containment. There was no specific UL nameplate located, but contact with <br /> Cummins in NMwaukee, WL confirmed that the tank is a UL 142 double wall secondary <br /> containment tank, and that the tank is 79 gallons capacity. UL 142 Secondary Containment tanks <br /> have long been recognized as having integral secondary containment, but UL 142 also has single <br /> wall tanks. This system was confirmed as having integral secondary containment by contacting <br /> the manufacturer. The secondary containment for this system is adequate to contain in excess of <br /> 1100/.of the primary tank capacity. Additionally, this entire system sits within a concrete berm <br /> which has additional containment of 125 gallons of liquid. This is adequate for the entire <br /> contents of the primary vessel plus freeboard precipitation. <br /> Miscellaneous: <br /> Security fencing is present, serviceable, and of adequate height. All operations, including tank <br /> filling operations, are contained within the secured areas, which is open during regular business <br /> hours. Site personnel have positive control of entry to all locations within this facility. <br />
The URL can be used to link to this page
Your browser does not support the video tag.