page 2, 1645 Cherokee Lane <br /> stabilize to +/-10% over two successive readings. In addition, groundwater monitoring <br /> analytical data with corresponding sampling event dates were not presented in a tabulated <br /> format in the quarterly monitoring report. Quarterly groundwater monitoring analytical <br /> data must be provided to PHS/EHD in all reports in a table showing every contaminant <br /> analyzed and chronological dates of sampling events. Data tables must be updated in <br /> each report to show the range of contaminant concentrations starting with the baseline <br /> sampling event and continuing to the most recent sampling event. <br /> In summary, soil contamination at this site appears defined in the area of the former diesel <br /> UST to a depth of forty feet bsg. TPHd contaminant levels were reported at 22,000 <br /> milligrams per kilogram (mg/kg) in the ten foot bsg sample and 2,000 mg/kg in the forty <br /> foot bsg sample. Water contamination at the site is currently monitored by three shallow <br /> monitoring wells located to surround the former UST areas. While the levels of <br /> contamination in the water samples are not high, the water contamination detected in the <br /> former diesel tank pit area during the URS Greiner Woodward Clyde investigation is <br /> currently not being monitored. Groundwater flow direction has changed over the two <br /> completed monitoring events from northwest to northeast. Future monitoring events <br /> should indicate what the predominant groundwater flow direction at this site is. The data <br /> collected to date indicate that another monitoring well is needed closer to the former <br /> diesel tank pit area, possibly located directly northwest from the URS Greiner Woodward <br /> Clyde boring labeled B-1. <br /> Submit a work plan for the installation of the additional monitoring well to PHS/EHD by <br /> July 23, 2001. Quarterly groundwater monitoring must continue at this site until directed <br /> otherwise by PHS/EHD. If you have any questions or comments please call Lori Duncan <br /> at(209)468-0337. <br /> Donna Heran, REHS, Director <br /> Environmental Health Division <br /> Lori Duncan, Senior REHS Dot Lofstrom, R.G. <br /> LOP/Site Mitigation Unit IV Engineering Geologist <br /> cc: Marty Hartzell, CVRWQCB <br /> Bill Motzer, HETI <br />