Laserfiche WebLink
Additional Soil and Groundwar5r Investigation Work Plan-Addendum <br /> CCT Stockton Rail Yard, 1645 Cherokee Lane,Stockton,California <br /> December 17, 2007 <br /> Page 2 <br /> As such, TRC has revised the plotted location of sample WWCSF-78 (Figure 4, Attachment 1) and <br /> adjusted the proposed boring location for one of the two borings previously proposed for the north <br /> side of the excavation boundary (Figure 5, Attachment 1). TRC has kept one of the previously <br /> proposed boring locations along the northeast side of the excavation boundary because this is <br /> reported to be in the downgradient direction. <br /> ONE GRAB GROUNDWATER SAMPLE ANALYSIS <br /> SJCEHD Comment Paragraph 4: <br /> SJC/EHD personnel went to the site...a grab groundwater sample was collected, but no <br /> documentation of, or laboratory analytical report for this sample was submitted with the CLS <br /> Report. <br /> TRC Response: <br /> After a thorough review of all electronic files provide to TRC by CCT and CLS, TRC was able to <br /> locate an analytical report that includes one water sample (GW-2) collected on September 2, 2005. <br /> Total petroleum hydrocarbons as gasoline were detected in sample GW-2 at a concentration of 510 <br /> micrograms per liter (µg/1). Total petroleum hydrocarbons as diesel were also detected in sample <br /> GW-2 at a concentration of 1,10o µg/1. In addition various volatile organic compounds and semi- <br /> volatile organic compounds were detected at low concentrations, below 50 µg/1. A copy of the <br /> analytical report is included in Attachment 2. <br /> SJC/EHD CONDITIONS <br /> SJCEHD Comment i, Paragraph 7: <br /> You understand and agree that the installation of groundwater monitoring wells may still be <br /> required. <br /> TRC Response: <br /> TRC understands that, pending the results of this investigation, groundwater monitoring wells may <br /> still be required. <br /> SJCEHD Comment 2, Paragraph 7: <br /> The proposed boring locations are to be moved for more appropriate collection of grab <br /> groundwater samples near the original source of the contamination from the former diesel <br /> underground storage tank(UST). <br /> TRC Response: <br /> TRC is proposing one additional boring location (for a total of 5 borings) in the middle of the <br /> excavation area, near the former location of the diesel UST. Due to the thick column of backfill that <br /> will be encountered in this proposed boring, no soil samples will be collected unless native soil is <br /> observed prior to encountering groundwater. This boring will be advanced primarily for the sole <br /> purpose of collecting a grab groundwater sample. <br />