My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001948
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
3535
>
3500 - Local Oversight Program
>
PR0544497
>
ARCHIVED REPORTS XR0001948
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 3:51:49 PM
Creation date
5/28/2019 3:28:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001948
RECORD_ID
PR0544497
PE
3528
FACILITY_ID
FA0003687
FACILITY_NAME
OLD TRUCK STOP, THE
STREET_NUMBER
3535
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
13206009
CURRENT_STATUS
02
SITE_LOCATION
3535 CHEROKEE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.« <br /> S <br /> Ox,2 <br /> ^r... <br /> ' ' lr <br /> 10 December 2004 <br /> ' <br /> ' AGE-NC Project No 97-0312 <br /> Tage 2 of 4 <br /> 'In addition, the large on-site domestic well was purged and sampled To purge the large domestic <br /> well, a drain valve was opened on the water storage tank and the pump was allowed to cycle on and ' <br /> off for approximately 15 minutes The small domestic well was out of service, the electrical service ' <br /> was disconnected and the distribution piping was truncated and capped _ ' <br /> E <br />' 2 2 COLLECTION OF GROUND WATER SAMPLES <br /> The depth to water In the monitoring wells was re-measured following purging to assure a minimum <br />' 80% recharge prior to sampling Water samples were retrieved from each purged'monitoring well <br /> using a Waterra inertial pump To sample the large domestic well,a sampling port was opened at the <br /> wellhead and samples were collected from the port while the pump was operating Each sample was <br />' transferred into four laboratory-supplied 40-milliliter (ml) EPA-approved volatile organic analysis <br /> (VOA)vials containing 0 5 ml 18%hydrochloric acid solution as a sample preservative,and Into one <br /> 1-liter amber bottle without preservative <br />' The samples were labeled, placed in a chilled container, and transported under chain of custody to <br /> - Cal Tech Analytical Laboratories,Inc (CTEL), a California Department of Health Services(DHS)- <br /> certified analytical laboratory, for analysis The samples were analyzed for <br /> Total petroleum hydrocarbons quantified as gasoline (TPH-g) and diesel (TPH-d) In <br /> taccordance with EPA Method 8015M, and , I <br /> • Benzene;toluene,ethylbenzene,and total xylenes(BTEX)and the fuel additives di-Isopropyl <br /> ` ether(DIPE),,ethyl tertiary-butyl ether(ETBE),methyl tertiary-butyl ether(MTBE),tertiary- <br /> 4 amyl methyl ether (TAME), tertiary-butanol (TBA), 1,2-dibromoethane (EDB), 1,2- <br /> dichloroethane (1,2-DCA); ethanol, and methanol in accordance with EPA Method 8260B" <br /> I <br /> 1 1 1 <br /> 3.0.' FINDINGS <br /> 1 <br /> I <br /> Ground water elevations were determined by subtracting the measured depths,to groundwaterfrom <br /> the surveyed casing elevations(Table 1) Ground water flow direction was determined by contouring ; <br /> the water elevations on a scaled site plan (Figure 3) Hydrocarbon impact to ground water was , <br /> assessed by laboratory analysis and field observations , <br /> 1 <br /> ! r Advanced GeoEnvironmental,Inc F <br /> I <br /> 1 f <br /> I 1 I y <br /> I <br /> 11 I I <br />
The URL can be used to link to this page
Your browser does not support the video tag.