Laserfiche WebLink
SCOPE OF WORK <br /> GROUND-WATER MONITORING WELLS <br /> TRACY DEFENSE DEPOT, TRACY, CALIFORNIA <br /> PART1 GENERAL <br /> 1.1 REFERENCES <br /> The publications listed below form a part of this Scope of Work (SOW) to the extent referenced. <br /> AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) <br /> ASTM C 150 (1994) Portland Cement <br /> ASTM C 387 (1987) Packaged,Dry, Combined Materials for Mortar and Concrete <br /> ASTM D 1586 (1984) Penetration Test and Split-Barrel Sampling of Soils <br /> ASTM D 1785 (1993)Poly(Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80, and 120 <br /> ASTM D 5088 (1990) Decontamination of Field Equipment Used at Nonradioactive Waste Sites <br /> ASTM D 5092 (1990) Design and Installation of Ground Water Monitoring Wells in Aquifers <br /> ASTM D 5299 (1992) Decommissioning of Ground Water Wells, Vadose Zone Monitoring <br /> Devices,Boreholes, and Other Devices for Environmental Activities <br /> CODE OF FEDERAL REGULATIONS (CFR) <br /> CFR 172 Hazardous Materials Table, Special Provisions, Hazardous Materials Communications, <br /> Emergency Response Information, and Training Requirements <br /> COMPREHENSIVE FIELD WORK PLAN <br /> Defense Distribution Region West(DDRW)-Tracy, Vol 1 of 2, Final Version 1.0, June 1996 <br /> 1.2 SUBMITTALS <br /> Government approval is required for the following submittals and shall be submitted by the <br /> Contractor prior to start of work. <br /> 02671-001 <br />