Laserfiche WebLink
The meters and methods used to analyze the water samples are <br /> summarized below in Table 3. <br /> Table 3. Meters and Analytical Methods <br /> Parameter/Constituent Meter/Laboratory Method <br /> pH YSI Model 556 MPS meter <br /> Total Dissolved Solids EPA Standard Method SM 2540C <br /> Electrical Conductivity YSI Model 556 MPS meter <br /> Sodium EPA Standard Method 200.7 <br /> Chloride EPA Standard Method 300.0 <br /> Total Coliform Organisms EPA Standard Method SM 9221 B <br /> Nitrogen <br /> Ammonia EPA Standard Method 4500NH3G <br /> Nitrite as nitrogen EPA Standard Method 300.0 <br /> Nitrate as nitrogen EPA Standard Method 300.0 <br /> Total Kjeldahl as nitrogen EPA Standard Method 351.2 <br /> Total Trihalomethanes EPA Standard Method 8260B <br /> Boron EPA Standard Method 200.7 <br /> Iron EPA Standard Method 200.7 <br /> Manganese EPA Standard Method 200.7 <br /> 3.0 GROUNDWATER MONITORING RESULTS <br /> Groundwater levels were measured in monitoring wells to assess changes in <br /> groundwater-flow directions, and analytical results from well water samples were <br /> used to assess changes in shallow groundwater chemical composition. During <br /> Third Quarter 2009 and prior to the groundwater monitoring event, recycled water <br /> was stored in Ponds A, B, and C and was discharged to Land Application Sites 1 <br /> and 2.3 No recycled water was discharged to Land Application Site 3. <br /> 3 Recycled water application records for land application sites, Aaron Winer, Veolia West <br /> Operating Services, written communication, September 8, 2009. <br /> - 9 - <br />