SAN J O A Q U I N Environmental Health Department <br /> -COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Delta Truck Center Body Shop 1 100 Transportation Ct, French Camp June 07. 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days. <br /> In the paint area, one black 30 gallon steel drum containing bondo dust(1/4 full)was observed with a hazardous <br /> waste label missing the accumulation start date. Facilities who generate less than 1000 kg of hazardous waste per <br /> month and do not exceed 6000 kg of waste stored on site at any time may store waste on site up to 180 days. <br /> Since it cannot be determined how long the hazardous waste has been on site, immediately contact a licensed <br /> hazardous waste hauler to dispose of this waste under manifest. Submit a copy of the manifest to the EHD within 30 <br /> days. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> In the main shop, one blue 55 gallon steel drum containing used oil filters(not crushed/punctured, '/4 full)was <br /> observed with a hazardous waste label missing the physical property, hazardous property, name and address of the <br /> generator,the correct accumulation start date, and the words"Hazardous Waste." <br /> In the paint area: <br /> -One black 30 gallon steel drum containing bondo dust(1/4 full)was observed with a hazardous waste label that <br /> was missing the accumulation start date and the hazardous property. <br /> -One black 55 gallon steel drum containing aerosol cans(full)was observed with a hazardous waste label missing <br /> the accumulation start date. <br /> -Two black 55 gallon steel drums containing paint filters(full, Y4 full)were observed with hazardous waste labels <br /> missing the accumulation start date. <br /> -One black 55 gallon steel drum containing solid paint waste(full)was observed with a hazardous waste label that <br /> had an incomplete accumulation start date of 3/15. <br /> -Two black 55 gallon steel drums containing paint waste(both full)were observed with hazardous waste labels <br /> missing the accumulation start date. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition(contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 7, 2019. <br /> FA0023800 PR0541516 SC001 06/07/2019 <br /> EHD 22-01 Rev.09/27/2018 Page 6 of 7 Small Quantity Hazardous Waste Generator QIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />