Laserfiche WebLink
Building 850 Septic System Closure Plan 2 11 August 2009 <br /> Lawrence Livermore National Laboratory Site 300 " <br /> San Joaquin County <br /> Building 850, operations involving the use of metals may have caused undocumented <br /> discharges of metals to the septic system. <br /> 2. Sample and analyze groundwater from upgradient monitoring well NC7-44 and <br /> downgradient monitoring well NC7-10 according to Table 2 below. <br /> 3. Within two months of conducting the sampling of soil and groundwater, submit sampling <br /> and analytical results to the Central Valley Water Board. <br /> 4. Propose completing a feasibility study to remediate the soil and/or groundwater within 60 <br /> days of reporting the results of the required monitoring if the analyses indicate that <br /> beneficial uses of groundwater are impacted or threatened to be impacted. <br /> Table 1:Building 850 se tics stem soil analytical methods and repo inlimits <br /> Analyte EPA (E) or Reporting Units <br /> Standard Method SM limit <br /> Aluminum E6010B or E6020 1 m /L <br /> Antimony E6010B or E6020 0.06 m /L <br /> Arsenic E6010B or E6020 0.05 m /L <br /> Barium E6010B or E6020 0.5 m /L <br /> Beryllium E6010B or E6020 0.04 m /L <br /> Boron E6010B or E6020 0.5 m /L <br /> Cadmium _ E6010B or E6020 0.05 m /L <br /> Chromium E6010B or E6020 0.5 m /L <br /> Chromium VI E218.6, E7196 or E200.8 0.05 m /L <br /> Cobalt E6010B or E6020 0.5 m /L <br /> Copper E6010B or E6020 0.5 m /L <br /> Iron E6010B or E6020 0.5 mg//L <br /> Lead E6010B or E6020 0.5 m /L <br /> Magnesium E6010B or E6020 0.5 mg/ L <br /> Manganese E6010B or E6020 0.05 m /L <br /> Mercury E6010B or E6020 0.005 m /L <br /> Molybdenum E6010B or E6020 0.5 m /L <br /> _Nickel _ E6010B or E6020 _ 0.5 mL <br /> Potassium E6010B or E6020 1 m /L <br /> Selenium E6010B or E6020 0.05 m /L <br /> Silver E6010B or E6020 0.5 m /L <br /> Thallium E6010B or E6020 0.02 m /L <br /> Vanadium E6010B or E6020 0.5 m /L <br /> Zinc JE6010B or E6020 0.5 m /L <br /> Or equivalent method as approved by the Central Valley Water Board. <br />