My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
0
>
2900 - Site Mitigation Program
>
PR0538882
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2019 10:00:14 AM
Creation date
6/18/2019 1:59:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0538882
PE
2960
FACILITY_ID
FA0022339
FACILITY_NAME
CITY OF TRACY CLASS II LAND TREATMENT UNIT
STREET_NUMBER
0
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
2531122
CURRENT_STATUS
01
SITE_LOCATION
CORRAL HOLLOW RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM FOR -6- <br /> CITY OF TRACY <br /> CLASS II LAND TREATMENT FACILITY <br /> SAN JOAQUIN COUNTY <br /> 2. Proposed conceptual design and location of water quality monitoring points includin; those at <br /> the point of compliance (§2550.7); <br /> 3. Proposed monitoring parameters, constituents of concern, and their monitoring frequencies <br /> (§2550.7 and §2550.8); <br /> 4. Proposed concentration limits and /or methods for establishing concentration limits <br /> (§2550.4); and <br /> 5. Proposed statistical methods for determining statistically significant evidence or a release <br /> from the land treatment units. <br /> GROUND WATER AND VADOSE ZONE MONITORING <br /> The ground water surface elevation (in feet and hundredths, M.S.L.) in all wells shall be measured <br /> each time a well is sampled and used to determine the velocity and direction(s) of ground water <br /> flow. This information shall be displayed on a water table contour map and/or ground water flow <br /> net for the site. At each monitoring event, the Discharger shall demonstrate compliance with the <br /> water quality protection standard. <br /> Ground water monitoring wells and vadose zone monitoring devices shall, at a minimum, be <br /> sampled and analyzed as follows: <br /> MONITORING FOR GROUND WATER AND VADOSE ZONE <br /> Sampling <br /> Report in & Reporting <br /> Parameter/Constituent Units of Frequency <br /> Specific Conductance (field) µmhos/cm Quarterly <br /> pH (field) pH units Quarterly <br /> Floating hydrocarbons presence or absence Quarterly <br /> Total Dissolved Solids mg/1 Quarterly <br /> Dissolved Organic Carbon mg/1 Quarterly <br /> Turbidity (except for vadose) mg/1 Quarterly <br /> Total petroleum hydrocarbons (TPH)' <br /> as gasoline µg/1 Quarterly <br /> as diesel µg/1 Quarterly <br /> Total recoverable petroleum µg/1 Quarterly <br /> hydrocarbons (TRPH)' µg/1 Quarterly <br /> Purgeable aromatics' µg/1 Quarterly <br />
The URL can be used to link to this page
Your browser does not support the video tag.