Laserfiche WebLink
KLE/NFELOER <br /> Bright Rap e.jtf_.:o.f <br /> analyses, the groundwater sample analyses shall include said analytes within its suite of <br /> analyses (shown below) to assess groundwater impacts. <br /> Groundwater <br /> The groundwater samples will be analyzed for the following: <br /> • Biochemical Oxygen Demand (BOD); <br /> • Volatile Organic Compounds (VOCs); <br /> • Semi-volatile organic compounds (SVOCs); <br /> • Total Dissolved Solids (TDS), <br /> • Total Petroleum Hydrocarbons in the gasoline range; <br /> • Total Petroleum Hydrocarbons in the diesel range; <br /> • Benzene, Toluene, Ethylbenzene, and Total Xylenes; <br /> • Nitrate <br /> • Nitrate as N <br /> • Polychlorinated biphenyls (PCBs); <br /> • Organochlorine Pesticides (OCPs); <br /> • Title 22 (CAM 17) Metals; <br /> • Chlorinated Herbicides; and <br /> • Organophosphorus Pesticides (OPPs). <br /> Groundwater sampled for CAM 17 metal analyses will be filtered using an in-line filter of <br /> 0.45 microns (Nm). The water samples will be handled under chain-of-custody control <br /> protocols and analyzed by a laboratory certified to perform the analyses. The water <br /> samples will be analyzed on a typical standard turnaround schedule requiring up to 12 <br /> working days. Please see the SAP in Appendix A for detailed sample collection <br /> protocols. <br /> After sampling is completed, the boreholes will be abandoned using grout in general <br /> accordance with regulatory requirements. If required, an inspector from the regulatory <br /> agency will be present. <br /> 128328/SAC14R0267 Page 8 of 11 July 12, 2013 <br /> Copyright 2013 Kleinfelder Revision 2-February 14,2014 <br />