Laserfiche WebLink
—• - KLEINFELDEZ <br /> B-2.6 Collection of BAT Probe Groundwater Samples <br /> One-time groundwater samples are collected using a BAT Probe, which is an insitu groundwater <br /> sampling device. The borings are first advanced to a point immediately above the desired <br /> sampling depth where groundwater is encountered. A stainless steel drive tip equipped with a <br /> stainless steel filter is lowered into the boring at the end of a 2.5-inch diameter galvanized steel <br /> pipe and pushed using the drill rig approximately 6 to 12 inches into the soil/aquifer formation at <br /> the bottom of the boring. A sterilized, glass, vacuum sealed sampling ampoule (tube), similar to <br /> a standard volatile organics (VOA) vial, is then lowered through the pipe down to the tip with a <br /> cable. Between the tip and the sample tube is a double-sided hypodermic needle (syringe),which <br /> simultaneously punctures the seals on the stainless steel drive tip and the septum of the glass <br /> sample ampoule. The vacuum in the sample ampoule draws groundwater through the tip into the <br /> glass ampoule. The glass ampoule is then pulled out of the pipe, disengaging the syringe. The <br /> septum in the glass ampoule and drive tip reseals after the syringe is removed. <br /> To reduce the potential for introducing contaminants into the samples, the drive tip, galvanized <br /> pipe, and other equipment used for sample collection are steam cleaned and/or washed with <br /> trisodium phosphate or non-phosphate detergent solution and double rinsed with distilled water <br /> prior to use. The sample probe and filters are cleaned in TSP solution and rinsed with methyl <br /> alcohol followed by a distilled water rinse prior to use. New, factory-sterilized syringe needles, <br /> O-rings, septum's and sample tubes are used for each sample. <br /> B-2.7 Sample Handling <br /> After labeling, the sample is immediately stored in an iced cooler for transport to Kleinfelder's <br /> office sample control or to the analytical laboratory. A Kleinfelder chain-of-custody form <br /> accompanies the cooler. The chain-of-custody form includes Kleinfelder's name, address and <br /> telephone number, the employee number of the individual who performed the sampling, the <br /> sample numbers, the date and time the samples were collected, the number of containers each <br /> sample occupies, the sample matrix (soil or water) and the analyses for which the samples are <br /> being submitted, if any. The chain-of-custody form is signed by each person who handles the <br /> samples, including all Kleinfelder employees and the receiving employee of office sample <br /> control or the analytical laboratory when the samples are delivered. <br /> B-2.8 Decontamination of Equipment <br /> To reduce the potential for cross-contamination, augers and associated equipment are steam <br /> cleaned prior to drilling each boring. In addition, sampling equipment is cleaned with a <br /> trisodium phosphate or non-phosphate detergent wash and rinsed with distilled water prior to <br /> collecting each soil sample. <br /> 20-YP1-628/2011P180 Page B-3 <br /> 0 2001,Kleinfelder,Inc. July 2,2001 <br />