Laserfiche WebLink
kn KLEINFELDER <br /> 52 and GPI) were found to exceed the State and Primary MCL of 13 and 5 µg/l, respectively <br /> ' TBA was detected in two groundwater samples at concentrations of 5 2 and 6 0 µg/1 (DW-50 and <br /> DW-52), which exceed the City's limit of 5 µg/1 <br /> Trans and Cis-1,2-DCE was detected in six groundwater samples, four of which had <br /> concentrations that exceed either State or Federal MCLs Trans-1,2-DCE was detected in four <br /> groundwater samples at concentrations ranging from 17 to 160 4g/1, which exceeds the State <br /> ' <br /> Primary MCL of 10 4g11 Trans-1,2-DCE detected at 160 µg11 from GP3 also exceeded the <br /> Federal MCL of 100 µg/1 Cis-1,2-DCE was detected in the same four groundwater samples at <br /> concentrations ranging from 21 to 140 µg/l, exceeding the State MCL of 6 µg/1 Cis-1,2-DCE <br /> ' was detected in the GP3 groundwater sample at 140 µg11 which exceeds the Federal MCL of 70 <br /> Fig/l <br /> ' TCE was detected in seven of the fourteen groundwater samples, two of which exceeded State <br /> and Federal MCLs TCE was detected at concentrations of 10 µg/1 (GP3) and 11 µg/1 (DW-54) <br /> ' which exceed the State and Federal MCL of 5 µg/l PCE was detected in a single groundwater <br /> sample DW-51 at a concentration of 13 µg/1, which exceeds the State and Federal MCL of 5 <br /> µg/l <br /> For additional information regarding the analytes detected, please refer to Table 1 and the <br /> laboratory data sheets in Appendix D <br /> 1 <br /> I 1 <br /> 1 <br /> I <br /> t <br /> 28699 EO1 1 ST03R759 Page 12 of 17 <br /> Copyright 2003,Klemfelder,Inc May 20,2003 <br />