Laserfiche WebLink
` Fourth Quarter 2005,Quarterly Groundwater Monitoring Report <br /> Pilkington North America,Inc.,Lathrop,CA <br /> Page 4 of 5 <br /> of Roseville, California. Laboratory analytical results from the November 9, 2005 sampling event are <br /> summarized in Table 2,below. <br /> Table 2—Laboratory Analytical Results (November 9,2005) <br /> j Constituent: TPH-D TPH-MO TPH-K <br /> Detection Limit: 0.05 0.50 0.25 <br /> In mg/L mg/L <br /> Sample ID <br /> MW=1 <0.05 <0.50 <0.25 <br /> MW-2 0.106* <0.50 <0.25 <br /> MW-3 <0.05 <0.50 <0.25 <br /> SW-Sump 2.44* <0.50 <0.25 <br /> SE-Sump <0.05 <0.50 <0.25 <br /> *The sample chromatographic pattern does not resemble the fuel standard for quantitation: <br /> Units: <br /> mg/L=milligrams per liter,parts per million(ppm) <br /> Analytical: <br /> TPH-D=total petroleum hydrocarbons quantified as diesel. <br /> TPH-MO=total petroleum hydrocarbons quantified as motor oil. <br /> TPH-K=total petroleum hydrocarbons quantified as kerosene. <br /> 1 <br /> f <br /> i FUTURE WORK <br /> Condor anticipates that continued quarterly groundwater monitoring will be required. In addition, <br /> recovery well water level and product thickness measurements should continue on a biweekly basis along <br /> with the diesel-recovery operations (bailing and SoakEZ® Socks). Active and passive skimmer recovery <br /> operations will continue when sufficient fluid column is present in the recovery wells to support product <br /> skimming. The next quarterly monitoring event is scheduled for February 2006. <br /> i . <br /> I <br /> i <br /> I - <br /> f , <br /> j <br /> f <br /> CONDOR <br /> i <br />