ARCHIVED REPORTS THIRD QUARTER GROUNDWATER MONITORING REPORT AUGUST 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
2900 - Site Mitigation Program
>
PR0009276
>
ARCHIVED REPORTS THIRD QUARTER GROUNDWATER MONITORING REPORT AUGUST 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2019 8:51:00 AM
Creation date
6/25/2019 8:25:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
THIRD QUARTER GROUNDWATER MONITORING REPORT AUGUST 2015
RECORD_ID
PR0009276
PE
2960
FACILITY_ID
FA0012033
FACILITY_NAME
PILKINGTON NORTH AMERICA
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19812008
CURRENT_STATUS
01
SITE_LOCATION
500 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> FURNACE BUILDING <br /> SW--SUMP SE-SUMP O <br /> ELEVATED DIESEL <br /> PIPING <br /> �I \Z = Q <br /> � aWZ <br /> APPROXIMATE RANGE OF HISTORIC GROUNDWATER GRADIENTS, 9' <br /> I � AVERAGE N 0.003 FEET/FOOT I O Q O <br /> U Lt <br /> Ld <br /> 1,000 GALLON RW-2 I Q (nJ <br /> 1 EMERGENCYz v <br /> Mw-1 GENERATOR <br /> I�` DIESEL TANK W O <br /> RW-8 k� Q <br /> Vph <br /> — O <br /> h 0 y <br /> Q <br /> W <br /> 2-1' FUEL (ABANDONED) �I <br /> (SUPPLY/RMRN) E <br /> FORMER FORKLIFT <br /> 3 FUEL <br /> W <br /> I i i j 3: -. ' � a <br /> FUELING t!7 <br /> ABANDONED — — — <br /> DISPENSERS ( W W <br /> - __. _- .. . . . -. _ - - - — o <br /> r <br /> RW-5 / k *0.17 1 !'\ O0 s <br /> CURRENT DIESEL ` <br /> , <br /> DISPENSER ` <br /> // � TEST <br /> /j/ SRW 4 PIT #1 j. <br /> I <br /> 1.4a i -3 � - <br /> 1.08 Y <br /> `a.r <br /> �r <br /> C, <br /> i r • ° I c <br /> Q <br /> i �' I. � F I a <br /> E <br /> 10,000 GAL o 0 t^ <br /> AST DISEL A5T ` ' ` ^ v' <br /> CONTAINMENT <br /> STRUCTURE n v <br /> €; 7 v cn a < <br /> E <br /> Ij U vLn0�ME a' <br /> y r_on r <br /> G R M M n u <br /> .,h,noo a <br /> r'" <br /> «P <br /> X0 <br /> - <br /> C N+' <br /> j omU��� <br /> x rnto cwwv r <br /> . .. St> ry 1hvx; <br /> GENERATOR WITH <br /> 700 GALLON E r <br /> LEGEIV® � oIESE�. TANK ' � o <br /> Q' u <br /> Mw-3 ca <br /> T: <br /> MW-1 _ (MW) MONITORING WELL (2" DIAMETER) <br /> (RW) RECOVERY WELL (4' DIAMETER) v <br /> a = FACILITY GROUNDWATER SUMP SAMPLING LOCATION NORTH <br /> FREE DIESEL PRODUCT IN WELL 0 30 FIGURE o <br /> 0 <br /> 0.17 m FREE PRODUCT TIiICKNESS IN WELL (IN FEET) ON 8/21/2015 SCALE IN FEET �E i <br /> NOTE: RW-1 WAS DAMAGED BY TRAFFIC IN 1999 G <br /> RW-6 WAS DAMAGED BY TRAFFIC IN 2014 <br /> a <br /> RW-5 WAS DAMAGED BY TRAFFIC IN 2015 <br /> File NO. <br /> 70648_FH_3Qt5 x <br />