Laserfiche WebLink
r <br /> I~ > Messrs Trommer and Luton 16 June 2008 <br /> Preliminary Five-Year Review Letters Page 4 of 7 <br /> Various Sites <br /> 1140 Hammer Lane, W. <br /> • The CUF has recommended review of the work plan to replace well MW-5 and <br /> evaluate additional remediation requirements; the EHD agrees with the <br /> recommendation, has reviewed.the workplan and issued a permit for destruction <br /> of the current MW-5. The well will be reinstalled approximately 30 feet south of its <br /> i current position. <br /> 1 D3 E Street, N. .y <br /> f ir! <br /> This site has been;previously commentedkon by the EHD and the EHD agrees <br /> F with the recommendation of the revised letter. <br /> f <br /> 2537 Waterloo Road, E. <br /> • <br /> The. CUF has recommended that the RP be directed to assess remedial <br /> technologies and implement active remediation without delay. The EHD has <br /> recently issued an approval for an interim corrective action plan and a work plan <br /> that incorporates a pump and treat system coupled with SVE/IAS; three <br /> additional monitoring wells are to be installed toward the west for additional <br /> plume delineation and two extraction wells are to be installed for remediation <br /> purposes.. <br /> 290 Main Street N. <br /> • CUF recommends implementing the approved remedial technology; the EHD <br /> agrees. The discharge permit for treated water has been obtained, but the <br /> building permit has not been issued by the City of Manteca; it is estimated that an <br /> additional four weeks or so willbe needed before construction is initiated. <br /> 545 Miner Street E. <br /> • CUF recommends closure consideration, the. EHD cannot agree at this time. <br /> f Recent vapor samples have exceeded the Tier. 1, Surfer ESLs and soil data for <br /> r <br /> TPHg, TPHd, naphthalene, benzene and xylenes exceed gross contamination; <br /> further evaluation. of the data is needed. The EHD will. direct the RP to <br /> demonstrate a relationship between the rioted contamination and the UST <br /> system release and to.evaluate potential remediation requirements. <br /> 595 11th Street E. <br /> • The CUF recommended closure consideration, the EHD agrees with this <br /> recommendation. The vapor intrusion evaluation has been performed. and <br /> reported to not be a. significant concern, a closure summary report has been <br /> submitted and.is-pending EHD review. <br /> 1001 Yosemite Avenue E. <br /> • The CUF recommends site closure consideration, the EHD agrees with' the <br /> recommendation.. A soil vapor investigation has been conducted, but not yet <br /> reported; a site closure summary report has been submitted, but is pending EHD <br /> review. <br /> 5-Year Review Comment Letter 061608.doc <br />