My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2800 - Aboveground Petroleum Storage Program
>
PR0528391
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2019 2:56:55 PM
Creation date
7/10/2019 9:50:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528391
PE
2832
FACILITY_ID
FA0007158
FACILITY_NAME
CDCR-DEUEL VOCATIONAL INSTITUTION
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
Rd
City
Tracy
Zip
95304
APN
23912001
CURRENT_STATUS
01
SITE_LOCATION
23500 Kasson Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CDCR-DEUEL VOCATIONAL INSTITUTION 23500 Kasson Rd,Trac June 12, 2019 <br /> Other Violations <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandon ment/lIlegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> -Three 2000 gallon diesel tanks at the boiler house are manifolded together. This was not addressed in the SPCC <br /> plan. <br /> -Table 3 of the SPCC plan states that the Vehicle Maintenance Garage would have up to one drum of new motor oil <br /> and one drum of transmission oil. Two drums of motor oil and one drum of used oil were observed in the Vehicle <br /> Maintenance Garage. <br /> -Table 3 of the SPCC plan states that the Used Oil Storage Area would have up to seven drums of used oil. Eleven <br /> drums of used oil were observed in the Used Oil Storage Area. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan must be amended when there is a change in the <br /> facility design, construction, operation, or maintenance that materially affects its potential for a discharge,within 6 <br /> months of the change, and implemented as soon as possible, not later than 6 months following preparation of the <br /> amendment. Immediately ensure that the SPCC Plan accurately represents the procedures and policies currently in <br /> place at the facility and submit proof to the EHD. <br /> Permanently manifolded tanks are tanks that are designed, installed, or operated in such a manner that the multiple <br /> containers function as a single storage unit(67 FR 47122, July 17, 2002).Accordingly, the total capacity of <br /> manifolded containers is the design capacity standard for the sized secondary containment provisions(plus free <br /> board in certain cases). <br /> This is a repeat violation, Class II. <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> -Tanks were not inspected on an annual basis. The SPCC plan requires annual inspections for the bulk storage <br /> containers. The last annual inspection for bulk storage containers was done on 1/17/2018. <br /> -Monthly inspections were not done on the 3000 gallon diesel and 2000 gallon gasoline tank at the Garage Fueling <br /> Station. <br /> Each aboveground container shall be tested and inspected for integrity on a regular schedule and whenever repairs <br /> are made. The qualifications of personnel performing tests and inspections,frequency and type of testing and <br /> inspections that take into account container size, configuration, and design shall be determined in accordance with <br /> industry standards. Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br /> testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br /> testing. Comparison records and other records of inspections and tests must be maintained on site. Immediately <br /> conduct the necessary inspections and submit a copy to the EHD, or provide equivalence as allowed by CFR <br /> 112.7(a)(2). <br /> This is a Class II violation. <br /> FA0007158 PR0528391 SCO01 06/12/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.