My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2800 - Aboveground Petroleum Storage Program
>
PR0528391
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2019 2:56:55 PM
Creation date
7/10/2019 9:50:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528391
PE
2832
FACILITY_ID
FA0007158
FACILITY_NAME
CDCR-DEUEL VOCATIONAL INSTITUTION
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
Rd
City
Tracy
Zip
95304
APN
23912001
CURRENT_STATUS
01
SITE_LOCATION
23500 Kasson Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY— <br /> Aboveground <br /> CUNTYAboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CDCR-DEUEL VOCATIONAL INSTITUTION 23500 Kasson Rd,Tracy June 12, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 714 CFR 112.8(c)(8)(kiv) Failed to provide each container with a high level monitoring device. <br /> The 2000 gallon diesel tank located at the PIA Farm Equipment Maintenance Shop had a broken liquid level gauge. <br /> At least one of the following devices must be installed in each container: <br /> -High liquid level alarm with audible or visual signal <br /> -High liquid level pump cutoff device set to stop flow at a predetermined content level <br /> -Direct audible or code signal communication between the container gauger and the pumping station <br /> -Fast response system, such as digital computer,telepulse, or direct vision gauge. If a direct vision gauge is <br /> being used for determining the liquid level of each tank, a person must be present to monitor gauges and the overall <br /> filling of the tanks. <br /> Immediately install an approved liquid level sensing device in accordance with CFR 112.8 and implement necessary <br /> procedures to ensure that the devices are fully functional and in use at all times during tank filling operations, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a repeat violation, Class II. <br /> 718 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br /> containers. <br /> The 55 gallon drums in the vehicle maintenance garage and the rental air compressor were observed with insufficient <br /> secondary containment. The rental air compressor did not have any secondary containment. Table 3 of the SPCC <br /> plan states that the maintenance bay provides secondary containment for the 55 gallon drums inside the vehicle <br /> maintenance garage. The maintenance bay is not sufficiently impervious. The underground section that the oil would <br /> flow into has a crack and ground water is infiltrating the area, per vehicle maintenance shop employee. Portable oil <br /> storage containers must be positioned or located to prevent a discharge and shall be furnished with a secondary <br /> means of containment sufficient to contain the capacity of the largest single container with sufficient freeboard to <br /> contain precipitation. Immediately provide sufficient secondary containment for this and all other portable containers <br /> at this facility, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 12, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> Inspector Provided: Return to Compliance certification, flier for free CUPA classes <br /> FA0007158 PR0528391 SCO01 06/12/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.