SANJ Q A Q U I N Environmental Health Department <br /> C: OuNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: I Facility Address: Oete: <br /> LDS-STOCKTON BISHOPS STOREHOUSE 3112 LOOMIS RD STOCKTON June 25 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item M Remarks <br /> 609 CFR 112.7(ay3vi),112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> The Spill Prevention,Control, and Countermeasure(SPCC)Plan does not provide information and procedures to <br /> enable a person to adequately report a discharge.The name and phone number of the California Office of Emergecy <br /> Services State Warning Center was not in the SPCC plan. If a response plan was not submitted to the Regional <br /> Administrator,this information must be included in the SPCC Plan. Immediately amend the SPCC Plan to include <br /> this information and submit a copy of the revision to the EH D. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 710 CFR 112.8(cx6)Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> The SPCC plan does not address or determine in accordance with industry standards,the appropriate qualifications <br /> for personnel performing tests and inspections,the frequency and type of testing and inspections,which take into <br /> account container size,configuration, and design. <br /> The interstitial space of the double walled tank is not being inspected. EPA has determined that the inspection of the <br /> interstitial for double walled tanks is the equivalent to inspecting the outside of the container for signs of deterioration, <br /> discharges,or accumulation of oil inside diked areas <br /> Test or inspect each aboveground container for integrity on a regular schedule and whenever you make material <br /> repairs.You must determine,in accordance with industry standards,the appropriate qualifications for personnel <br /> performing tests and inspections,the frequency and type of testing and inspections,which take into account container <br /> size,configuration, and design(such as containers that are:shop-built,field-erected,skid-mounted, elevated, <br /> equipped with a liner,double-walled,or partially buried).Examples of these integrity tests include,but are not limited <br /> to:visual inspection,hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing,or other <br /> systems of non-destructive testing.You must keep comparison records and you must also inspect the container's <br /> supports and foundations. In addition,you must frequently inspect the outside of the container for signs of <br /> deterioration,discharges,or accumulation of oil inside diked areas.Records of inspections and tests kept under usual <br /> and customary business practices satisfy the recordkeeping requirements of this paragraph. <br /> The SPCC plan should indicate what industry standard the tanks fall under and determine,in accordance with industry <br /> standards,the appropriate qualifications for personnel performing tests and inspections,the frequency and type of <br /> testing and inspections,which take into account container size,configuration,and design. <br /> This is a repeat violation,Class If. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EH with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by July 25, 2019 <br /> FMW37W PRO53UU 50301 06252019 <br /> MAD28-01 R—OV27=18 Page 5of6 Alwvgj JPetro—Sbra)e AC OIR <br /> 1868 E. Hazelton Avenue I Stockton,California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehdCom <br />