My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0007668
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
400
>
3500 - Local Oversight Program
>
PR0544653
>
ARCHIVED REPORTS XR0007668
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2019 7:18:10 PM
Creation date
7/11/2019 2:42:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007668
RECORD_ID
PR0544653
PE
3528
FACILITY_ID
FA0004695
FACILITY_NAME
BRIDGESTONE/FIRESTONE #3573
STREET_NUMBER
400
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95201
APN
13907009
CURRENT_STATUS
02
SITE_LOCATION
400 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Firestone Serywe Center 400 North El Dorado, Stockton, Cahfornua <br /> February 2, 1994 Sod Remediation Plan—2072.01 Page 5 of 6 <br /> 3.4 Permitting <br /> Permits required to operate the system will be obtained prior to installation <br /> Applicable permits will be obtained from the following agencies <br /> • San Joaquin County Public Health Services <br /> • San Joaquin County Air Pollution Control District <br /> 1 • City of Stockton Public Works Department <br /> 35 Site Closure Criteria <br /> Since the soil sample analytical results from the October 1993 site assessment <br />' indicate non-detectable quantities of TVPH, RMI proposes to determine site closure <br /> based upon analysis of system vapor discharge and monitoring point(s) vapor <br /> concentrations The regulations establish a compliance level for soil based upon a <br /> site rating system The maximum allowable hydrocarbon level for soil remaining in <br /> place at this site, as determined by The Leaching Potential Analysis, Table 2-1 in <br /> the CA-LUFTManual, is 100-ppm TPH-gas, or TVPH Since the regulations do not <br /> identify an action level for soil gas, it is suggested that a target level for soil gas <br /> concentration be set at 100-ppm TVPH as determined by EPA Method TO-14 <br /> Once the target soil gas concentration is achieved, the active well will be turned <br /> off to allow for recharge of vapors After a minimum of a 1 week system off-time, <br /> vapors will be extracted from the idle well to determine if recharge has occurred <br />' If soil gas concentrations remain below the 100-ppm target level, soil gas samples <br /> from any impacted monitoring points with corresponding depths will be analyzed <br /> to verify concentrations are below the target level Each well system will be <br /> handled similarly, although operation time may differ <br /> System operations will proceed as follows <br /> iInitially, vapors will be extracted from well VE 2 until soil gas concentrations reach <br /> the target level At this point, well VE 2 will be disconnected and vapors will be <br /> extracted from well VE 1 Once target levels have been achieved in VE 1 , the VES <br />' unit will be reconnected to extract vapors from VE 2 Extracted vapors from VE 2 <br /> will be sampled immediately after restart If vapor concentrations have not <br /> increased above the target level after pulsing the well, as described herein, <br /> extraction at this well will be terminated Well VE 1 will then be reconnected <br /> following similar procedures Once it has been shown that soil gas vapors are not <br />' recharging during system shut-off times, site closure will be requested <br /> RYAN-MURPHY, INCORPORATM Deaver <br /> Emkomnentai Coon Management I" Angebs <br /> r <br />