r u] <br /> Page 9 F-1 000 <br /> 4.5 INSTALLING THE MOLDED IN-"LINE FITTING (MI) <br /> All molded in-line (MI) fittings have male American National Standard Taper Pipe Threads(MPT) <br /> • Select an area on the pipe as outlined in section 4 1 <br /> •Install the F-1000 as you would any other plastic pipe fitting Be sure the inlet and outlet fittings are aligned <br /> properly Improper alignment of the fittings will put stress on the adapter connections and may cause <br /> leaking or fitting damage Do not over tighten the fittings Use Teflon®tape sealant only on the adapter <br /> threads <br /> •The F-1000 can be mounted on horizontal or vertical runs of pipe Mounting at the twelve o'clock position <br /> on horizontal pipe is recommended Mounting anywhere around the diameter of vertical pipe is acceptable, <br /> however, the pipe must be completely full of water at all times See figure 4, 5 and 6 <br /> •Be sure the inlet and outlet plumbing is properly secured The F-1000 is not designed to support the weight <br /> of related piping Improperly supported pipes will put stress on the adapter connections and may cause <br /> leaking or fitting damage <br /> � xs� {camMen <br /> ominal Pipe$ ,� `"": �° > gh 1Hesght 86 5 r <br /> r <br /> M. 318 MPT-low flow 473 52T Molded in-line body <br /> 318" 318'MPT-std flow 4 73' 538 H with M P T <br /> 112* 112'MPT-low flow 509 5 38- Pe <br /> 11Y 1I2'MPT-std flow 509 538' <br /> 314 314'MPT4ow flew 5 25' 558' <br /> 314- 314 MPT-std flow 525, 557 <br /> 10, 1 0"MPT-low flow 565 657 <br /> 10, 1 0 MPT-std flow 5 65" 557" <br /> L. ._- _-..� Fig 10 <br /> 4.6 HOW TO INSTALL MOLDED PVC <br /> TEE FITTINGS (TE) <br /> •Select an area on the pipe as outlined in section 4 1 <br /> •Remove the F-1000 sensor from the tee fittingDo not glue the me�' ' �' v 1 �°�Irr e' 4- <br /> g Hom �PYpe`� l a� T� <br /> TEE while the sensor is installed. T"�@ �� <br /> •Install the F-1000 tee fitting as you would any other plastic 1 4" s- <br /> 1-12' 4-1/2 6-518• <br /> pipe solvent weld(glue) fitting Do not use too much glue- <br /> Z 4-314 7-118• <br /> Excessive glue may create a disturbance in the flow stream <br /> which will effect the accuracy of the meter <br /> •The F-1000 can be mounted on horizontal or vertical runs of <br /> pipe Mounting at the twelve o'clock position on horizontal ;�ar6as, <br /> pipe is recommended Mounting anywhere around the diame- <br /> ter of vertical pipe is acceptable, however, the pipe must be H Tee FdHng <br /> completely full of water at all tunes See figure 4, 5 and 6 <br /> •Install the F-1000 sensor Be sure two O-nngs are located on -� <br /> the sensor body The 0-rings have been lubricated at the Nominal <br /> factory with silicone oil Push the sensor assembly into the Pipe Size <br /> saddle with a twisting motion The notch on the sensor body <br /> must fit into the slot on the saddle Be sure the sensor is fully L .---1 <br /> inserted into the saddle HAND TIGHTEN the union nut Fig. 11 <br />