R604 :UPDATE 16 2-23-1993 <br /> in volt seconds, and assigns a peak number and retention time. <br /> The sum of all the responses are then used to obtain a mg/L per <br /> volt second calibrant factor. This factor is used to calculate <br /> mg/L as gasoline vapor from each analysis . Pounds per day can <br /> be computed using these mg/L values, and the pressure <br /> differential created at the orifice (flow rate) for each well, <br /> and total influent . Since September 25, 1992, tedlar bag samples <br /> are obtained and brought back to be analyzed in the WEGE portable <br /> laboratory. This is necessary due to long eluting time (analysis <br /> time increased from 10 minutes per sample to 30 minutes per <br /> sample) needed per analysis using the 10s50 (all early eluding <br /> compounds have been removed by vapor extraction) . The pounds per <br /> day values for each well and the influent are then averaged to <br /> the preceding site visit' s pound per day value and then <br /> multiplied by the number of days the system operated between <br /> visits to estimate the total pounds each well and the total <br /> system has removed for that time period. This poundage is then <br /> added to the accumulated poundage of the previous visit to update <br /> the total pounds removed to date, see Table 3 and Appendix B . <br /> Sampling Vapor Streams: <br /> The vapor samples are obtained by attaching a dedicated air tight <br /> soft polytubing to a sample port on the well side of the orifice <br /> plate on the vapor recovery manifold. The tubing is then <br /> connected to a tedlar bag placed inside a vacuum sampler. The <br /> sample port is then opened and the vacuum placed on the tedlar <br /> bag from the sample vessel allows the tedlar bag to fill with the <br /> vapor stream from that particular sample port . Once the tedlar <br /> �,. bag is full the valve is closed and the vacuum removed from the <br /> sample vessel . The tedlar bag contains an air tight locking <br /> septum valve which is then closed and locked to secure the vapor <br /> sample. A small dedicated needle attached to a dedicated 1 cc <br /> syringe is then inserted through the sample septum into the <br /> tedlar bag. The lcc syringe is purged numerous times before <br /> filling it with the sample. All but 0 . 5 cc of the sample is <br /> ejected into the air before injecting the remaining 0 . 5 cc <br /> syringe sample into the Shimadzu FID-GC (the calibrant injection <br /> is 0 . 5 cc) . Once the chromatogram is recorded, an instrument <br /> blank is run prior to the next sample. The instrument blank will <br /> indicate if residual peaks are being carried onto the next <br /> analysis . <br /> Vacuum influent readings are obtained from the wells by attaching <br /> a manometer calibrated in mm water to sample ports at the well <br /> heads . These readings show the mm water pressure or vacuum that <br /> is being created at each well . <br /> page 5 <br />