• Mr. Harlin Knoll <br /> San Joaquin County Public Health Services, <br /> Environmental Health Division <br /> Page 2 <br /> May 18, 1995 <br /> 0.285 ppm, 0. 610 ppm, 0 . 064 ppm, 0 . 540 ppm, respectively in soil <br /> samples collected from the floor of the excavation at a depth of <br /> approximately 21 feet. TPHg, EDB, and organic lead were not <br /> detected. The excavated soil was aerated, sampled, confirmed clean <br /> and returned to the excavation pit. <br /> In October 1990, four soil borings (B-1 through B-4) were drilled <br /> at the site, and one soil boring (B-5) was drilled on the adjacent <br /> property owned by Hammertown Partners (Hammertown) . The soil <br /> borings were drilled to a depth of approximately 40 feet bgs. <br /> Benzene and ethyl benzene were detected at concentrations of 0 . 024 <br /> ppm and 0. 0062 ppm, respectively in boring B-1 at a depth of <br /> approximately 25 feet. BTEX were detected at concentrations of <br /> 0.405 ppm, 1. 33 ppm, 0 .440 ppm, and 2 . 38 ppm, respectively in <br /> boring B-2 at a depth of approximately 30 feet. BTEX were not <br /> detected an soil samples collected from the other sample intervals <br /> from borings B-1 and B--2. TPHg was not analyzed in soil samples <br /> collected from borings B-1 and B--2 . TPHg and BTEX were not <br /> detected in soil borings B-3 and B-4 . Benzene, toluene, and <br /> ethylbenzene were detected at concentrations of 0 . 068 ppm, 0 . 037 <br /> ppm, and 0. 011 ppm, respectively in soil samples collected from <br /> offsite boring B-5 at a depth of approximately 25 feet bgs. Xylene <br /> and TPHg were not detected. TPHg and BTEX were not detected in <br /> soil samples collected from the other sample intervals in boring B- <br /> 5. <br /> In April 1992 , three additional soil borings (NBH #1 through NBH <br /> #3) were drilled at the site and three additional soil borings (HBH <br /> #1 through HBH #3) were drilled on the Hammertown site. The <br /> borings were drilled to approximately 36 . 5 feet bgs. Soil samples <br /> collected from the borings were analyzed for BTEX. BTEX were not <br /> detected in borings NBH #1 through NBH #3 , HBH #1 or HBH #3 . <br /> Benzene was detected at a maximum concentration of 0 . 028 ppm at <br /> depths ranging from 26. 5 to 31. 5 feet bgs in soil samples collected <br /> from boring HBH #2 , located on the adjacent Hammertown property <br /> approximately 20 feet south of the former UST excavation. Toluene, <br /> ethylbenzene, and xylenes were detected at concentrations of 0 . 017 <br /> ppm, 0. 008 ppm, and 0 . 019 ppm, respectively in soil samples <br /> collected from boring HBH #2 . The limits of soil contamination <br /> were defined by these soil borings, except in a southerly direction <br /> on the Hammertown property. <br />