Laserfiche WebLink
SAN JOAQUIN Environmental Health Department <br /> IJ NIT Time In: 10-40 am <br /> ry Time Out: 11:52 am <br /> SclForit' Greotness grows here. <br /> Food Program Service Request Inspection Report <br /> Name of Facility: DEUCES SPORTS BAR Date: 06/19/2019 <br /> Address: 26247 THORNTON RD , THORNTON 95686 <br /> Requestor: KEVIN MCDONALD, STEVEN PASIONENRIQUEZ.COM Telephone: <br /> Program Element: 1601 -FOOD PLAN CHECK Request#: SR0080610 <br /> Inspection Type: 523-Plan Check/Report Review <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate closure of <br /> the food facility. <br /> #21 Hot and Cold Potable Water Not Available <br /> OBSERVATIONS:Bar 3 comp sink has temp at 114F. provide 120F or above today. <br /> CALCODE DESCRIPTION:An adequate,protected,pressurized,potable supply of hot water and cold water shall be provided at all times. <br /> (113953(c), 114099.2(b) 114101(a), 114189, 114192, 114192.1, 114195) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Women rest room hand sink is draining slowly. Repair today. <br /> Pipes, draining the bar 3 comp sink and hand sink in the floor sink, are lacking air gap. Provide air gap 1 inch at least off the <br /> floor sink today. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #43 Toilet Facilites Clean/Supplied/Maintained <br /> OBSERVATIONS:Women and men rest rooms are lacking paper towels dispensers. Provide paper towels dispensers for <br /> women and men rest rooms today. <br /> Both rest rooms are lacking self closing doors. Provide self closing doors in 1 week. <br /> CALCODE DESCRIPTION:Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a <br /> well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet <br /> facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons:in <br /> establishments with more than 20,000 sq ft. establishments offering on-site liquor consumption. (114250, 114250.1, 114276) <br /> FA0003068 SR0080610 SC523 06/19/2019 <br /> EHD 16-23 Rev.06/30/15 Page 1 of 2 Food Program Service Request Inspection Report <br />