Laserfiche WebLink
Geofagualrlecfi�cus Inc Page 5 <br /> Valentine(Castle Motors) <br /> Vertical Def WP <br /> August 23, 2000 <br />' between three readings) indicating that formation water representative of aquifer conditions is <br /> entering the well These water quality parameters are measured at intervals of each well <br /> volume purged <br /> A stainless steel or disposable plastic bailer will be used to collect each sample Care will be <br /> taken to minimize sample agitation from the initial filling of the bailer to the transfer of the <br /> sample to the VOA vial and glass amber liter bottles Once the sample container is filled and <br /> capped, the bottle will be inverted, tapped, and checked for headspace bubbles The sample <br /> container is identified and labeled with a unique designation, inserted into foam holders and <br /> placed in an ice chest cooled to 4°C for transport to the laboratory <br /> All non-disposable sampling equipment is decontaminated using a steam cleaner before and <br /> between uses The effectiveness of the decontamination procedure is ensured by using the <br /> following quality control measures <br /> • Disposable gloves will be used by the technician to collect all samples and will be <br /> changed with each sampling event <br />' • A bailer blank for each well will be collected prior to sampling by filling the <br /> decontaminated stainless steel bailer with water (provided by the laboratory) and then <br /> filling a VOA vial (provided by the laboratory) using the same procedures for actual <br /> sample collection <br /> Bailer blanks for each sample, along with a field blank (prepared from water provided by the <br /> laboratory poured into a VOA vial on site), will accompany the samples to the laboratory and <br /> serve as checks against cross contamination <br /> A chain of custody document, listing all samples collected, accompanies the samples from <br />' field to laboratory, thereby providing a means to track their movement and ensure their <br /> integrity <br /> All water purged from each monitoring well and not used as a sample, will be placed in a 55 <br />' gallon DOT approved container, properly labeled and stored on site <br /> 2.5 Groundwater Sample Analyses <br />' One groundwater sample from each well will be submitted to CLS Laboratories (State <br /> Certified Laboratory 91233) and analyzed for <br /> • Benzene, toluene, ethylbenzene and xylene (BTEX) by EPA method 8020 <br /> • Gasoline range petroleum hydrocarbons (TPH-G) by EPA method 8015(m) <br /> • Fuel oxygenates (MTBE, TBA, DIPS, ETBE and TAME) by EPA method 8260 <br /> • 1,2 DCA, EDB, methanol and ethanol by EPA method 8260 <br /> IThe detection limits for these compounds are listed below A Chain of Custody will be <br /> completed for all samples collected and tracked to ensure sample integrity <br />' Detection Limits BTEX Ethers -U 1,2--DCA & EDB MethanolEthano <br /> Water dig <br /> 1 <br /> • <br /> 1 <br /> 1 <br />