Laserfiche WebLink
P.O.Box 4208 <br /> Sonora CA 95370 <br /> AiltechPetr'"6- j� <br /> Ca:623541 -73 a0 <br /> Phone:209-532-730 <br /> Compliance without Compromise �- �� tan :., Fax:209-533-265x, <br /> mail@alltechpetro.com <br /> A�w.jllt6ch�.4 �4.com <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information s�,NJo�,cr,';S.Cc�LlNrr <br /> Facility Name: Costco # Village West Marina Date of Testing/Servicing: March 23, 2011 I"°,LTH C`_a, sTtv4C�JT <br /> Facility Address:6649 Embarcadero, Stockton CA 95217 <br /> Facility Contact Person: Mike Spence Facility Phone: (209) 951-1551 <br /> LIA: San Joaquin Health; Inspector: Garrett Backus; LIA Phone: 209-468-9847; LIA Fax: 209-468-3433 <br /> Make/Model of Monitoring System: Veeder-Root TLS-3501 LIA Email: gbackus@sjcehd.com <br /> B. Inventory of Equipment Tested/Certified: <br /> Tank ID: Premium 91 Tank Tank ID: Diesel Tank <br /> ❑In-Tank Gauging Probe. Model: None ❑In-Tank Gauging Probe. Model: None <br /> ®Annular Space Sensor. Model: 794380-344 ®Annular Space Sensor. Model: 794380-344 <br /> ❑Piping Sump Sensor(s). Model: 792380-208 ®Piping Sump Sensor(s). Model: 792380-208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: VMI LD-2000 ®Mechanical Line Leak Detector. Model:VMI LD-2000 <br /> ❑Tank Overfill/High-Level Sensor. Model: Flapper Valve ®Tank Overfill/High-Level Sensor. Model: Flapper Valve <br /> ® Fillspill Bucket Tested: ®Pass ❑Fail ® Fillspill Bucket Tested: ®Pass []Fail <br /> ❑ Fire extin uishers ins ected and tagged: ❑OK❑Not OK ❑ Fire extinguishers inspected and tagged: ❑OK ❑Not OK <br /> Tank ID: Tank ID: None <br /> ❑ In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space Sensor. Model: ❑Annular Space Sensor. Model: <br /> ❑Piping Sump Sensor(s). Model: [:]Piping Sump Sensor(s). Model: <br /> F1 Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑ Line Leak Detector. Model: ❑ Line Leak Detector. Model: <br /> F1 Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Fillspill Bucket Tested: El Pass ❑Fail ❑ Fillspill Bucket Tested: ❑Pass ❑Fail <br /> ❑ Fire extinguishers inspected and tagged: ❑OK ❑Not OK ❑ Fire extinguishers inspected and to ed: ❑OK [—]Not OK <br /> Dispenser ID:Transition Sump ® Sump: ®Dry[]Water❑ Dispenser ID: 1 ® Sump: ®Dry❑Water❑Product <br /> Product ®Dispenser Containment Sensor(s). Model: Float&Chain <br /> ®Dispenser Containment Sensor(s). Model: 792380-208 ®Shear Valve(s) (Functional test) <br /> r_1 Shear Valve(s) (Functional test) ❑ Fire extinguisher inspected and tagged: ❑OK []Not OK <br /> ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br /> Dispenser ID: 2 ® Sump: ®Dry❑Water❑Product Dispenser ID: 3 ® Sump: ®Dry❑Water❑Product <br /> ®Dispenser Containment Sensor(s). Model: Float&Chain ®Dispenser Containment Sensor(s). Model: Float& Chain <br /> ®Shear Valve(s) (Functional test) El Shear Valve(s) (Functional test) <br /> ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br /> Dispenser ID: ❑ Sump: ❑Dry❑Water ❑Product Dispenser ID: ❑ Sump: ❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: Ll Dispenser Containment Sensor(s). Model: <br /> F-1 Shear Valve(s) (Functional test) E]Shear Valve(s) (Functional test) <br /> ❑ Fire extinguisher ins ected and tagged: ❑OK ❑Not OK ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br /> Dispenser ID: ❑ Sump: ❑Dry []water []Product Dispenser ID: ❑ Sump: ❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> F1 Shear Valve(s) (Functional test) E]Shear Valve(s) (Functional test) <br /> ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is a Plot Plan showing the layout of monitoring equipment. For any equipment capable of <br /> generating such reports, I have also attached a copy of the report; ® System set-up ®Alarm history report <br /> �0Technician: Date: 3/23/2011 <br /> Certification: Veeder-Root B36878, Level 4 <br /> ICC UST Service Technician # 8005930-UT <br />