COMPLIANCE INFO 2004 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EMBARCADERO
>
6649
>
2300 - Underground Storage Tank Program
>
PR0231098
>
COMPLIANCE INFO 2004 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2019 8:52:05 AM
Creation date
7/24/2019 4:44:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2011
RECORD_ID
PR0231098
PE
2361
FACILITY_ID
FA0003830
FACILITY_NAME
VILLAGE WEST MARINA
STREET_NUMBER
6649
STREET_NAME
EMBARCADERO
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
09815006
CURRENT_STATUS
01
SITE_LOCATION
6649 EMBARCADERO DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Facility Name: Village West Marina (Page 2) <br /> D. Results of Testing/Servicing <br /> Complete the following checklist: <br /> Software Version Installed: 324.01 <br /> ❑Yes ❑ No* Is the audible alarm operational? <br /> [E Yes ❑ No* Is the visual alarm operational? <br /> [Z Yes ❑ No* Is the print function operational? <br /> ❑Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> ®Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other <br /> equipment will not interfere with their proper operation? <br /> El Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. <br /> ® N/A modem) operational? <br /> ®Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> ❑ N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If <br /> yes: which sensors initiate positive shutdown? (Check all that apply) ® Sump Sensors; ❑ <br /> Dispenser Containment Sensors. <br /> Did you confirm positive shutdown due to leaks and sensor failure/disconnection? ® Yes; ❑ No. <br /> ❑Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device, is <br /> ❑ N/A the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? At <br /> what percent of tank capacity does the alarm trigger? <br /> ❑ ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other <br /> equipment replaced and list the manufacturer name and model for all replacement parts in Section <br /> Yes* E, below. <br /> EJ Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all <br /> that apply)❑ Product; ❑ Water. If yes, describe causes in Section E, below. <br /> ®Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if <br /> applicable <br /> ®Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> E. Comments: <br />