1 <br /> Report of Investigation <br /> Former Underground Storage Tanks <br /> 3105 South Fl Dorado Street Stockton,California <br /> Sierra-Pacific Project No 96-620 Ot <br /> 1 <br /> 1 3.5.1 Soil Sample Analyses <br /> One soil sample collected from three of the four soli borings was analyzed for total petroleum <br /> 1 hydrocarbons as gasoline (TPH-g) by EPA Method 8015-modified, and for benzene, toluene, <br /> ethylbenzene, and total xylenes (BTEX) and for MTBE by EPA method 8020 The results of these <br /> 1 analyses are presented in Table 1 and in the text of Section 4 2 <br /> 3.5.2 Ground Water Sample Analyses <br /> Ground-water grab samples from soil borings B-3 and B-4, and the sample collected from the ground- <br /> 1 water momtonng well MW-2 were analyzed for TPH-G, BTEX, and MTBE The sample from MW-2 <br /> was also analyzed for TPH as motor oil(TPH-o) Results of these analyses are presented in Table 2, and <br /> in the text of Section 4 3 <br /> M <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> .Sierra-Pacific Groundwater Consultants, Inc 8 <br /> 1 <br />