PE
3528
FACILITY_ID
FA0006247
FACILITY_NAME
Western Lift
STREET_NUMBER
3430
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17525063
CURRENT_STATUS
02
SITE_LOCATION
3430 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
was collected from the well and analyzed for total petroleum <br /> hydrocarbons (TPH as gasoline and diesel) and volatile aromatics <br /> ' (BTE&X) . TPH contamination was detected in the water sample and the <br /> San Joaquin County Public Health Services - Environmental Health <br /> Division (PHS/EHD) required further groundwater assessment. The <br /> 1 results of the initial monitoring well installation and sampling <br /> were detailed in a report submitted to the PHS/EHD dated June 26, <br /> 1992 . <br /> Two additional monitoring wells were installed by GeoAudit on <br /> November 12 , 1992 . one well was installed south of the warehouse, <br /> near the southern boundary of the property (near the Manna Pro <br /> facility) . The other monitoring well was installed east of the <br /> former tank excavation. Installation and sampling procedures and <br /> results were described in the "Groundwater Monitoring Well <br /> Installation Report" dated January 8, 1993 . <br /> 2.5 Groundwater Depth and Gradient <br /> On November 24 , 1992 , the depth to groundwater was measured, the <br /> three wells were purged and samples were collected. Because of a <br /> possible laboratory labeling error, on January 22 , 1993 , a <br /> replacement sample was collected from monitoring well MW-3 . <br /> At the time of sampling, depth to groundwater was approximately 42 <br /> feet in each well. The gradient was determined to be 0. 008 ft/ft, <br /> oriented N 410 W. <br /> 2 .6 Laboratory Results <br /> ' Groundwater samples collected during the November 1992 sampling <br /> event were analyzed for TPH and BTE&X. Laboratory analyses reported <br /> 1 concentrations of TPH as gasoline, benzene and toluene in MW-1 of <br /> 220 gg/1, 15 µg/l and 0. 30 pg/l respectively. No TPH as gasoline, <br /> benzene or toluene was reported in MW-2 or MW-3 . TPH as diesel was <br /> reported in MW--3 at a level of 140 pg/l. However this result is <br /> 1 thought to be the result of a laboratory labeling error. The <br /> January 1993 replacement sample for MW-3 showed no diesel <br /> contamination. <br /> 3.0 PROCEDURES <br /> 3. 3 Drilling <br /> on June 17 , 1993 , two additional monitoring wells were installed on <br /> ' the Cutter Lumber property to the north of monitoring well MW-1. <br /> 14W-4 was installed near the southeast corner of the Cutter Lumber <br /> office, north-northwest of monitoring well MW-1; MW-5 was installed <br /> at the west edge of the property, northwest of monitoring well MW-1 <br /> (see Figure 2 - Site Plan) . <br /> 2 <br />