Laserfiche WebLink
Pilot Testing Report and Conceptual Corrective Action Plan July 15, 1994 <br /> Manna Pro, 4004 South EI Dorado, Stockton, CA <br />' TABLE 7 <br /> COMBINED GROUNDWATER PUMPING AND HVIE TEST <br />' FOURTH STAGE AQUIFER RESPONSE DATA <br /> October 26, 1993 <br />' Test Pumping Rate 3 75 gpm <br /> Vacuum/Flow ("Hg/SCFM) 15-23/200 <br />' Maximum Drawdown - EW-1 (r = 0) 2 38 feet <br /> Maximum Drawdown - OB-1 (r = 9 5 feet) 1 54 feet <br />' Maximum Drawdown - OB-2 (r = 13 feet) 1 51 feet <br /> Maximum Drawdown - 08-3 (r = 24 feet) 0 44 feet <br />' Maximum Drawdown - MWA (r = 51 feet) 0 69 feet <br /> Maximum Drawdown - MW-3 (r = 844 feet) 0 05 feet <br />' Well Yield Per Foot of Drawdown 1 57 gpm <br /> Well Yield At Optimum Drawdown 15 7 gpm <br /> "Hg/scfm Inches of mercury/standard cubic feet from minute <br /> r Radial distance from extraction well <br /> 2e79Ro34 opo 00 <br /> GROUNDWATER <br /> TECHNOLOGY, INC <br />