Laserfiche WebLink
Pilot Testing Report and Conceptual Corrective Action Plan July 15, 1994 <br /> Manna Pro, 4004 South EI Dorado, Stockton, CA <br />' TABLE 9 <br /> AQUIFER DATA ANALYSIS RESULTS <br />' COMBINED GROUNDWATER PUMPING AND HVE <br /> October 26, 1993 <br />' Apparent <br /> Distance from Hydraulic Apparent <br /> Monitoring Pumping Well Apparent Conductivity Transmissivity <br />' Well (feet) Storatrvity (gpd/ft2) (gpd/ft) <br /> EW-1 N/A N/A N/A N/A <br /> OB-1 95 0 007 116 1,156 <br /> OB-2 13 0 001 80 1 800 <br /> OB-3 24 0 006 334 3,335 <br /> Maximum <br /> Groundwater/HVDPE Estimated Average Average Average <br />' Pumping Rate Aquifer Apparent Apparent Apparent <br /> 3 75 gpm Thickness Storativity Conductivity Transmissivity <br /> at EW-1 = 10 ft = 0 005A 177 1 1,764 <br /> N/A = Data not available <br />' 2e19Ro34 opo <br /> GROUNDWATER <br />' TECHNOLOGY, INC <br />