My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
30703
>
2800 - Aboveground Petroleum Storage Program
>
PR0515652
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2019 10:57:16 AM
Creation date
7/31/2019 1:22:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515652
PE
2832
FACILITY_ID
FA0006475
FACILITY_NAME
TRACY MATERIAL RECOVERY/TRANSF
STREET_NUMBER
30703
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
25313019
CURRENT_STATUS
01
SITE_LOCATION
30703 S MACARTHUR DR
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Continuous Release Detection Method (CRDM) <br /> One (1) SWRI 93-01 listed Trusco maker & brand Aboveground Storage Tank, which is: (1) <br /> Elevated AST with (2) Integral Double-Wall Secondary Containment on Aboveground Storage <br /> Tank (3) Overfill protection, electronic product inventory monitoring and visual inspections <br /> being performed, (4) continuous mechanical float gauge leak detection. <br /> Spill Protection <br /> Product off load area is contained by Spill Containment Operations in which filler uses camlock <br /> connections, with overfill containment bucket for overfill operations, At time of inspection <br /> there was no known shut down device or limiting devices, such as Morrison Bros or a Guillotine <br /> fill limiting devices as a further protection against overfilling. . <br /> Overfill Prevention <br /> (1)Ullage Logs (2)Ullage Monitor(3) Baker Box Overfill Container <br /> Report of Findings <br /> Tank Containment <br /> This Clear Diesel Fuel Tank is <br /> located on a concrete pad. The <br /> Aboveground Storage Tank is <br /> SwRI 93-01 Tank, listed as <br /> Aboveground Storage Tank for <br /> Flammable Liquids, under SwRI <br /> 103 93-01 Standard for Protected <br /> Tanks with an Integral Secondary <br /> Containment Aboveground <br /> Storage Tank (AST). The general <br /> condition of the primary <br /> " containment is good and the <br /> secondary containment vessel is in <br /> good shape without any evidence <br /> of leaks, fractures, or corrosion <br /> affecting containment. There are <br /> areas of minor to moderate to substantial corrosion with the Body of the tank that should <br /> be repainted soon as part of the ongoing & normal preventative maintenance operations. <br /> The corrosion is external only, as located in this tank and has not impacted the steel <br /> thickness of the outer shell. The corrosion on the supports does not impact the integrity of <br /> the supports in any fashion, but should be monitored and if the corrosion worsens, then <br /> that issue should be addressed, the corrosion removed and the supports repainted. This <br /> external corrosion does not currently impact the stability of the tank nor the containment <br /> integrity of the tank. Oct 18, 2019: Tank has been repainted & corrosion has been removed <br />