Laserfiche WebLink
N <br /> Quarterly Report - Third Quarter 2005 <br /> ENTERPRISE INVESTMENTS (Former J.B. Murphy Trucking) <br /> (( 355 Enterprise Place,Tracy, California <br /> �< f <br /> 1.0. INTRODUCTION t, <br /> k; <br /> At the request of Mr.Monty Warren of Enterprise Investments,Advanced GeoEnvironmental,Inc. <br /> 'i (AGE)has prepared this quarterly report for 355 Enterprise Place,Tracy, California(site). The site <br /> E ' and surrounding area are illustrated on Figure 1.Structures,borings,and well locations are illustrated <br /> on Figure 2. Site background information is provided in Appendix A. <br /> f <br /> 2.0. PROCEDURES <br /> Five ground water monitoring wells(MW-I through MW-5) and one ground water extraction well <br /> (EW-1) were monitored and sampled on 01 September 2005. Field work was performed in <br /> r <br /> accordance with guidelines issued by the Central Valley Regional Water Quality Control Board <br /> (CVRWQCB) for the investigation of underground storage tanks (UST) sites. <br /> j <br /> 2.1. WELL MONITORING AND PURGING <br /> A Solinst water level meter was used to measure the depth to ground water in wells MW-1 through <br /> MW-5 and EW-1 relative to the tops of the well casings. The ground water elevations and gradient <br /> were determined from this data(Table 1). <br /> After recording water level measurements, disposable plastic bailers were used to purge wells }' <br /> { MW-1, MW-3, MW-4 and MW-5 of standing water; a Waterra inertial pump was used to purge <br /> MW-2 and a 3-stage pump was used to purge EW-1 of standing water.Approximately 5 to b gallons <br /> of water (a minimum of three casing water volumes per well) were removed from wells MW-1, H <br /> MW-3,MW-4,and MW-5,approximately 12 gallons of water were removed from well MW-2,and <br /> approximately 54 gallons of water were removed from well EW-1. Ground water temperature,pH, <br /> and conductivity were measured at regular intervals during purging using an Oakton water analyzer. <br /> Purged ground water was containcrized in properly labeled, Department of Transportation <br /> (DOT)-approved 55-gallon drums and stored on-site. Field sheets and data are included in <br /> Appendix B. <br /> pp �i <br /> F.: <br /> 2.2. COLLECTION OF GROUND WATER SAMPLES <br /> i <br /> E <br /> Water samples were collected from purged wells MW-1, MW-3, MW-4, MW-5 and EW-1 using <br /> j dedicated disposable plastic bailers,and a water sample was collected from MW-2 using a dedicated <br /> tubing,after allowing all wells to achieve a minimum 80%recovery of the pre-purge water volume. <br /> "} Each water sample was transferred into three 40-milliliter(ml)volatile organic analysis(VOA)vials <br /> Advanced GeoEnvironmental,Inc. I <br /> a <br />