My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2016 TANK TOP UPGRADE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
INSTALL 2016 TANK TOP UPGRADE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2019 3:32:32 PM
Creation date
8/2/2019 2:31:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2016 TANK TOP UPGRADE
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
November 21, 2016 <br />LC SERVICES <br />3887 N VALENTINE <br />FRESNO, CA 93702 <br />San Joaquin County <br />Environmental Health Department <br />1868 E Hazelton Avenue <br />Stockton, California 95205 <br />Website: www.sjcehd.com <br />Phone: (209) 468-3420 <br />Fax: (209) 464-0138 <br />RE: 7 -ELEVEN INC #19976 MANTECA, CA 95336 <br />DIRECTOR <br />Linda Turkatte, REHS <br />ASSISTANT DIRECTOR <br />Kasey Foley, REHS <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Rodney Estrada, REHS <br />Willy Ng, REHS <br />B FILE copy <br />Sent by Email and Certified Mail <br />SR0074936 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the application for a permit to conduct a tank top upgrade (existing tanks will remain and existing <br />UST monitoring will be reused) on the entire underground storage tank (UST) system (tanks 87- <br />octne and 91 -octane) at the above noted address. <br />The proposed work consists of the following major upgrades: installation of single wall Xerxes fill <br />and turbine sumps, installation of double wall Smith NOV (Red Thread IIA) fiberglass <br />underground piping, installation of OPW single wall under dispenser containments (UDCs), <br />installation a new monitored single wall Bravo vent box and all associated Smith NOV (Red <br />Thread IIA) fiberglass piping, installation of NOV penetrations, installation of OPW spill <br />containers, installation of OPW drop tubes with flapper valves, installation of an external Veeder <br />Root overfill alarm, installation of new Gilbarco dispensers, and installation of new line leak <br />detectors (VMI 99LD-2000S). According to LC Services, all existing sensors will remain at their <br />original location and one vent box Veeder Root (VR -208) sensor will be added to the existing <br />monitoring system; no conversion frames and no ball floats will be installed during this tank top <br />upgrade. <br />The permit has been approved with the following conditions: <br />1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District <br />for any applicable permits and requirements. <br />2. Any changes shall be submitted to the EHD for approval prior to commencing work. All <br />new submittals supersede the previous ones. <br />3. Contact Elena Manzo at (209) 953-7699 to arrange the following appointments (a 48- <br />hour notice is required for inspection appointments): <br />❑ Existing piping removal and soil sampling <br />❑ Primary piping soap test of all piping and penetrations (product and vent): One-hour <br />pneumatic pressure test at 110% of operating pressure, or 40 psi, whichever is <br />greater. <br />❑ Secondary piping slope (at 1/8- inches per foot or greater) to a containment sump <br />with an audible/visual alarm. <br />❑ Secondary piping soap test of all piping and penetrations (product and vent): One- <br />hour pneumatic pressure test at the manufacturer's recommended pressure. <br />❑ Verification of pipe setbacks and burial depth according to the manufacturer's <br />installation instructions. Verification of appropriate backfill. <br />❑ Verification of the dispenser footprints contained by the under dispenser containment <br />sumps (UDCs) <br />7 -ELEVEN INC #19976, 1399 N MAIN ST, MANTECA, CA 95336 SR0074936 <br />
The URL can be used to link to this page
Your browser does not support the video tag.