My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 11:51:06 AM
Creation date
8/5/2019 9:15:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SW'RCB, Januar}, 2002 <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specie) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Veeder Root TLS -350 <br />Equipment Resolution: 2417 <br />s <br />"Tank # T-4 87 <br />Tank # T-5 91 <br />Tank # Tank # <br />Is Tank Exempt From Testing?' <br />® Yes ❑ No <br />® Yes ❑ No <br />❑ Yes ❑ No ❑ Yes ❑ No <br />Tank Capacity: <br />15,000 gal <br />10,000 gal <br />Tank Material: <br />D.W. Fiberglass <br />D.W. Fiberglass <br />Tank Manufacturer: <br />Xerxes <br />Xerxes <br />Product Stored: <br />87 unleaded <br />91 Premium <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />0 IL <br />A G 0 7 2017 <br />Test Start Time: <br />Initial Reading (Rj): <br />ENVIRONMENTAL HCALT <br />Test End Time: <br />DEPARTMENT <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF-Ri): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail ❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ®No ❑ NA <br />[:]Yes ®No ❑ NA <br />❑ Yes ❑ No ❑ NA Dyes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ties No <br />® DNA <br />Dyes ®No DNA <br />Dyes ❑No DNA ❑1'es El -,o DNA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1. Above tanks are brine filled tank annulars. <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. { Cal ifomia Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.