My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 11:51:06 AM
Creation date
8/5/2019 9:15:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ❑ Hydrostatic <br />❑ Other (Spec) <br />"fest Equipment Used: INCON SUMP TESTER Equipment Resolution: 0.002" <br />.T <br />Fi1I Sump # T 487 <br />-S 91 <br />Fill Sump # <br />Fill Sump # <br />Sump Diameter: <br />42" <br />42" <br />Sump Depth: <br />58" <br />58" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />20" <br />23" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />12" <br />12" <br />Condition of sump prior to <br />testing: <br />Dry <br />Dry <br />_ <br />Portion of Sump Tested <br />2"/ Penetrations <br />2"/ Penetrations <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 min <br />10 min <br />Test Start Time: <br />11:10am <br />11:10am <br />Initial Reading (R,): <br />5.3164" <br />3.9477" <br />Test End Time: <br />11:25am <br />11:25am <br />_ <br />Final Reading (RF): <br />5.3165" <br />3.9472" <br />Test Duration: <br />15min <br />15min <br />Change in Reading (RF -Rt): <br />+0.0001" <br />-0.0005" <br />Pass/Fail Threshold or Criteria: <br />+I- 0.002" <br />+1-0.00211 <br />+!- 0.002" <br />+/- 0.002" <br />Test Result: <br />N Pass ❑ Fail <br />M Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Is there a sensor in the sump? <br />M Yes ❑ No <br />M Yes ❑ No <br />❑ Yes ❑ No <br />❑ Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑Yes ❑No NNA <br />❑Yes ❑No MNA <br />❑Yes ❑No DNA <br />Dyes [:]No DNA <br />Was sensor removed for testing? <br />MYes ❑No DNA <br />NYes [:]No DNA <br />❑Yes [:]No DNA <br />❑Yes ❑No DNA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes [:]No DNA <br />®Y"es ❑No DNA <br />[-]Yes ❑No DNA <br />❑Yes ❑No [:INA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />