Laserfiche WebLink
%[j7C�7gi NITORING SYSTEM CERTIFICATION <br />Fo, . By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3 Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: 7 -ELEVEN # 19976 MKT 2237 <br />Site Address: 1399 N. MAIN ST. <br />@ NORTHGATE <br />Facility Contact Person: MANAGER <br />Make/Model of Monitoring System: TLS350PLUS <br />City: MANTECA <br />Contact Phone No:239-3252 <br />Date of Testing/Service: 10/24/2001 <br />Work Order Number: 2219064 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />CA Zip: 95336 <br />Tank ID: RUL <br />Tank ID: MUL <br />X In -Tank Gauging Probe. <br />Model: MAG1 <br />X In -Tank Gauging Probe. <br />Model: MAG1 <br />X Annular Space or Vault Sensor. <br />Model: 794390420 <br />Annular Spate or Vault Sensor. <br />Model: 794390420 <br />X Piping Sump/Trench Sensor(s). <br />Model: 794380208 <br />Piping Sump/Trench Sensor(s). <br />Model: 794380208 <br />Fiji Sump Sensor(s). <br />Mouel: --- <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: VAPORLESS <br />Mechanical Line Leak Detector. <br />Model: VAPORLESS <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and model in Section E on page 2). <br />Otherc equipment <br />(s pe rfY type and <br />model in Section E on page 2). <br />Tank ID: PUL <br />Tank ID: <br />X In -Tank Gauging Probe. <br />Model: MAG1 <br />7In-Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. <br />Model: 794390420 <br />Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 794380208 <br />Piping Sump/Trench Sensor(s). <br />Model: <br />Fill Sump Sensor(s), <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />X Mechanical Line Leak Detector. <br />Model: FE PETRO <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Dispenser : 1/2 <br />Dispenser ID: <br />FTI Dispenser Containment Sensor(s) <br />Model: 794380208 <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ Shear Valve(s). <br />Shear Valve(s) <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 3/4 <br />Dispenser ID: <br />0 Dispenser Containment Sensor(s) <br />Model: 794380208 <br />Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) <br />Mode!: ___ _. <br />Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />' If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): System set-up report, ❑X Alarm history report X❑ <br />PRINTED NAME -DAVID MATHIE <br />SIGNATURE: , <br />COMPANY: Tanknology PHONE NO: (800) 8004633 <br />page 1 of 3 Based on CA form dated 03/01 <br />