My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 1998 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 3:46:44 AM
Creation date
8/8/2019 2:04:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2004
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Address: 1399 N. MAIN ST. <br />a) NORTHGATE <br />D. Results of Testing/Servicing <br />Software Version Installed: 119.05 <br />Complete the following checklist: <br />Mk oring System Certification <br />Date of Testing/Service: 10/24/2001 <br />X Yes <br />No <br />Is the audible alarm operational? <br />Yes <br />No <br />Is the visual alarm operational? <br />Yes <br />F71No <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />❑ Yes <br />1:1 No ' <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment wi!I nct <br />interfere with their proper operation? <br />Yes <br />No' <br />N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />© Yes <br />❑ No <br />N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />detects leak, fails <br />monitoring system a to operate, or is electrically disconnected? If yes: which sensors initiate positive <br />shut -down? (check all that apply) ❑X Sump/Trench Sensors; ❑X Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑x Yes ❑ No <br />❑ Yes <br />No <br />❑ N/A <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e.: no mechanical <br />overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill points(s) and operating <br />properly? If so, at what percent of tank capacity does the alarm trigger? <br />❑ Yes* <br />© No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E, below. <br />© Yes* <br />❑ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (check all that apply) ❑ Product; <br />❑x Water. If yes, describe causes in Section E, below. <br />© Yes <br />❑ No <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. <br />❑ Yes <br />❑ No <br />Is all monitoring equipment operational per manufacturers' specifications? <br />In Section E below, describe how and when these deficiences were or will be corrected. <br />E. Comments: <br />SUMPS RUL AND PUL WATER CLEANED OUT <br />REWIRED ANNULER AND SUMP ON RUL; WIRED ANNULER AS SUMP ;SUMP AS ANNULER <br />page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.