My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
INSTALL 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 4:39:40 AM
Creation date
8/8/2019 2:05:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
cj <br /> FLEXIBLE ENTRY BOOT (TYP.) <br /> COAX TEST TUBE PART N0. FEB-3157 <br /> SUMP <br /> SUMP LOW VOLTAGEJUNCTION BOX._ SUMP SEE NOTE N0. 3 <br /> CTT-3836 <br /> _COAX TEST TUBE (EXPLOSION PROOF) EXP <br /> CTi-3836 LOSION PROOF PUMP <br /> JUNCTION BOX CROUSE--HIND ELE n <br /> COAX PIPE ADAPTER NOTE: 42" SUMP BASE WALL... GUH 25 OR EQUAL. <br /> OPCATIONTIONAL <br /> DI FUTURE STP FOR LIQUID ASSEMBLY <br /> PART NO. CPA-1520 I I <br /> LIQUID PROBE OPTIONAL DISPENSER EXPANSION SENSOR ASSEMBLY <br /> SENSOR ASSEMBLY 0 -- ---- - <br /> ° ° o COAX PIPE ADAPTER ° ° COAX PIPE ADAPTER <br /> ° ° o ° ` ° o ° PART NO. CPA-1520 22" FLANGED MANWAY o o PART NO. CPA-1520 <br /> ° - <br /> 22_" D MANWAY PART NO. GFP-2150 & CPC-1520 22" FLANGEDNGED MANWAY —0 o DOUBLE WALL FLEXIBLE PIPE AND COAX COUPLING ° w/3-4" NPT FIii1NGS(2 SPARE) <br /> w/3 44"" NNPPT FITTINGS ° w/3-4" NET FITTINGS ( I ° — DOUBLE WALL FLEXIBLE PIPE AND COAX COUPLING ° I ° DOUBLE WALL FLEXIBLE PIPE AND COAX COUPLING <br /> (2 SPARE) o Q 4"o X 1.5" GEODUCT ENTRY BDOT (2 SPARE) o PART NO. GFP-2150 & CPC-1520 0 0 PART NO. GFP-2150 & CPC-1520 <br /> ° PART NO. GDB-7450 WITH DONUT ° � DOUBLE WALL FLEXIBLE PIPE <br /> LOW VOLTAGE MONITORING o PART NO. RRD-4015-D LOW VOLTAGE MONITORING olk s0 4" X 1.5" GEODUCT ENTRY BOOT 0 PART NO. GFP-2150 <br /> JUNCTION BOX. ° JUNCTION BOX, __ �. — PART NO. GDB-7450 WITH DONUT o " " 0 7-ELEVEN, INC. <br /> (EXPLOSION PROOF) - 0 0 GEODUCT FLEXIBLE CONDUIT (EXPLOSION PROOF) 0 1 PART NO. RRD-4015-D o I o GEODUCT FLEXIBLE CONDUIT CITYPIACE CENTER EAST <br /> 0 0 <br /> PART NO. GDP-4500-1 ° ° ° o o GEODUCT FLEXIBLE CONDUIT o ° PART N0. GDP-4500-1 711 N.S.iHASKELL <br /> DALDOUBLE WALL FLEXIBLE PIPE <br /> PART NO. GDP-4500-1 4" X L5" GEODUCT ENTRY BOOT 42" SUMP BASE WALL — PART NO. GFP-2150 PART NO. GDB-7450 WITH DONUT <br /> PART NO. RRD-4015-D <br /> DOUBLE WALL FLEXIBLE PIPE 42" SUMP BASE WALL- <br /> 1 E3LE ENTRY BOOT (IYP.) --_ 1 PART NO, GFP-2150 <br /> PART N0. FEB-3151 <br /> PARTFI-EXCOAX TEST TUBE <br /> EXPLOSION PROOF PUMP SEE. NOTE N0. 3 __. EXPLOSION PROOF PUMP <br /> ( ) JUNCTION BOX CROUSE-HIND JUNCTION BOX CROUSE-HIND CTT-3838 <br /> FLEXIBLE ENTRY BOOT TYP. REVISION: GATE: <br /> PART N0. FEB-3157 <br /> SEE NOTE N0, 3 GUH 25 OR EQUAL. GUH 25 OR EQUAL. <br /> - -- -- <br /> 30I.D. 30" I.D. 30" I.D. - <br /> TANK SUMP COVER AND TANK SUMP COVER AND <br /> TANK SUMP COVER AND p 42" DIA. MANHOLE & COVER GASKET SEAL 2 42" DIA. MANHOLE &. COVER GASKET SEAT_ 2 42" DIA, MANHOLE & COVER <br /> GASKET SEAT_ <br /> z z - <br /> h — <br /> m °-° NOTE -- °' 4 I E <br /> _.._ ❑ LOCATION OF FUTURE STP FOR ❑ <br /> �\ U OPTIONAL DISPENSER EXPANSION 3 z U 3 z o <br /> �l <br /> TURBINE ENCLOSURE tO N TURBINE ENCLOSURE IO uCi TURBINE ENCLOSURE 'O <br /> w/FIELD BONDED JOINT w/FIELD BONDED JOINT r -T 3 w/FIELD BONDED JOINT 3 <br /> PROBE WIRE PROBE WIRE <br /> 1 � x PROBE WIRE 1 x <br /> LIQUID PROBE SENSOR ASSEMBLY " a LIQUID PROBE SENSOR ASSEMBLY ~a <br /> COAX PIPE ADAPTER n w LIQUID PROBE SENSOR ASSEMBLY . " <br /> WTE-42 SUMP AS SPECIFIED---. CPA-1520 < ❑ WTE-4'2 SUMP AS SPECIFIED----. L_.J� COAX PIPE ADAPTER o COAX PIPE ADAPTER o <br /> CPA-1520 CPA-1520 <br /> -COAX COUPLING I' COAX COUPLING WTE-42 SUMP AS SPECIFIED COAX COUPLING <br /> CPC-1502 I I� y CPC--1502 j CPC-1502 m <br /> NOTE:.._._-- m __ — 14 _—. ED <br /> m m <br /> STP RISER MUST BE CUT TO STP NOTE: <br /> MUST DE CUT TO 1 z NOTE: z <br /> STP RISER MUST BE CUT 70 <br /> ul <br /> PROPER LENGTH TO PUT STP PROPER LENGTH i0 PUT STP PROPER LENGTH TO PUT STP <br /> PUMP & MOTOR ASSEMBLY 4" -- PUMP & MOTOR ASSEMBLY 4" _ PUMP & MOTOR ASSEMBLY 4" <br /> FROM THE BOTTOM OF THE TANK `D FROM THE BOTTOM OF THE TANK �' -' - - °p FROM THE BOTTOM OF THE TANK m <br /> GEODUCT ENTRY BOOT -- GEODUCT ENTRY BOOT .a <br /> GDB-7450 WITH DONUT �� GDB-7450 WITH DONUT GEODUCT ENTRY 1300T <br /> _ GDB-7450 WITH DONUT E., <br /> STP RISER THREADS DIRECTLY 2"x2"x2" GALVANIZED "TEE" STI' RISER THREADS DIRECTLY 2"x2x2"" GALVANIZED 'TEE" W <br /> 22" I.D. MANWAY FITTING (SEE DETAILS BELOW) 22" I.D. MANWAI STP RISER UNG. T DIRECTLY 22" LD. MANWA 2"x2" GALVANIZED q <br /> INTO MANWAY BUNG. ATTACHMENT -- INTO MANWAY BUNG, ATTACHMENT - FITTING (SEE DETAILS BELOW) INTO MANWAY BUNG. ATTACHMENT ELBOW' FITTING <br /> FLANGE MUST BE TESTED 42" LD. COLLAR COAX TEST TUBE FLANGE MUST BE TESTED A LD. COLLAR FIANCE MUST BE TESTED 0.. <br /> CTT X TES COAX TEST TUBE 42" I.D. COLLAR COAX TEST TUBE <br /> CTT-3836 CTT-3836 p <br /> a <br /> NOTE: AFTER COMPLETION OF LINE TESTING ALL DONUTS NOTE: AFTER COMPLETION OF LINE TESTING ALL DONUTS NOTE: AFTER COMPLETION OF LINE TESTING ALL DONUTS 0. <br /> TO BE LOOSENED AND PULLED BACK TO ALLOW FOR TO BE LOOSENED AND PULLED BACK TO ALLOW FOR TO BE LOOSENED AND PULLED BACK TO ALLOW FOR W <br /> PRODUCT MIGRATION TO SUMP — PRODUCT MIGRATION TO SUMP PRODUCT MIGRATION TO SUMP <br /> v) <br /> SECTION THRU SUMP SHOWING SUBMERGED SECTION THRU SUMP SHOWING SUBMERGED SECTION THRU SUMP SHOWING SUBMERGED <br /> TURBINE PUMP INSTALLATION TURBINE PUMP INSTALLATION TURBINE PUMP INSTALLATION <br /> 4 MPENSERS 6 MSPENSERS 8 MPENSERS <br /> (1 ) 2 H . P . SUB - PUMP 2 H . P . SUB - PUMP 2 ) 2 H . P . SUB - PUMPS <br /> ALLOW FOR FUTURE SUB-PUMP <br /> 2" X 2" GALV. <br /> 2" BALL SHUT (Di CENTRAL <br /> STREET IELBOW 4" SfP RISER---- OFF VALVE EQUIPMENT SCHEDULE <br /> DIVISION: <br /> 2" RISER _ <br /> TO STP / ITEM DESCRIPTION MANUFACTURER, PART NO. FURNISHED BY <br /> 2" RISER 2" RISER Cl) 2 X 2" BALL SHUT OFF VALVE ENVIRON PART NO. BSV-2020 7-ELEVEN, INC. <br /> 2 LEAK DETECTOR (VAPOR VALVE) VAPORLESS PART NO. 99LD-2000-RS 7-ELEVEN, INC. <br /> 2" BALL SHUT 4" STP RISER 3 2 HORSEPOWER SUBMERGED PUMP FE PETRO PART NO. STP VS2 7-ELEVEN, INC. <br /> OFF VALVE 4 LIQUID SENSOR VEEDER-ROOT PART NO. 794380-322 7-ELEVEN, INC. <br /> 4" STP RISER <br /> 2" X 2" X 2" <br /> TEE FITTING NOTES AND WARNINGS!!! <br /> 2" CLOSED NIPPLE <br /> 2" CLOSED NIPPLES1 . ALL PENETRATIONS THRU TURBINE ENCLOSURE MUST <br /> - 2" X 2" STREET ELBOWS BE MADE BY QUALIFIED CONTRACTOR. THIS INCLUDES <br /> BALL SHUT (� ELECTRICAL CONDUIT. <br /> -- 2" <br /> OFF VALVE 2. ALL TURBINE ENCLOSURES MUST BE INSTALLED AS <br /> RECOMMENDED BY MANUFACTURER'S INSTALLATION ISSUE DATE: <br /> INS]RUCTIONS. <br /> _ 4" BUNG <br /> 2" CLOSED NIPPLES 3. ALL ELECTRICAL TO BE ABOVE FUEL LINE PENETRATIONS. <br /> STORE NO: <br /> 4. ALL PENETRATIONS MUST BE INSTALLED AS RECOMMENDED <br /> 2" X 2" GALV. ll�j - BY MANUFACTURER'S INSTALLATION INSTRUCTIONS OK D BY: <br /> STREET ELBOWS <br /> APPROVED BY: <br /> le 1pTc-�� 03/13/03 <br /> COAX PIPE ADAPTER � P Q U DATE ISSUED: <br /> u nws __ <br /> — PART NO. CPA- 1 502 _ -- DRAWN BY <br /> - = NOTE <br /> SEALANT AROUND AI_ L. SUMP PENETRATIONS <br /> SHALL BE BOSTICK BRAND SPEC NO. FS 920. SHEET NO. <br /> --- PLUMBING TREE ASSEMBLY FOR �2) STP ASSEMBLY FOR <br /> DUAL PIPE LINES TO. PUMP CONNECTIONS DUAL PIPE LINES TO PUMP CONNECTIONS G7.0 <br /> FOR 6 DISPENSERS OR LESS FOR -a- DISPENSERS OR MORE <br /> OF 19 SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.