Laserfiche WebLink
1�{ <br /> 2" GALVANIZED SCH 40 VENT <br /> 12" 01A. x 2'-0" GONG. .___ RISER AT 12' ABOVE GRADE <br /> --BURIED BASE (TYP.) (P/V VENT PER LOCAL CODE) - 2" ELL <br /> 2" DIA. x 8'-0' GALVANIZED 2" UNION THEN NIPPLE <br /> SCH 40 SUPPORTS 4" x 2" DOUBLE & 90' ELBOW ELEVE n <br /> TAP BUSHING <br /> r' u-BOF_rs <br /> T-0" ABOVE GRADE (TYP.) 2" FIBERGLASS <br /> (TYP.) PIPE W/3" SECONDARY CONTAINMENT PIPE <br /> — — --- - 2" ENVIRON BALL VALVE #BSV-2020 <br /> OR EQUAL. MUST BE RATED FOR USE <br /> WITH ALCOHOL BLEND FUELS. <br /> 1/8" x 4° x 18" <br /> UNI-STRUTS SLAVE 2" x 3/8" BUSHING FOR COPPER LINE <br /> 2" DIA. - 90' AT 3' AND 5' TANK END 2" NIPPLE 7-ELEVEN, INC. <br /> GALVANIZED ELI_ ABOVE GRADE \ CITYPNCE CENTER EAST <br /> ELECTRICAL CONDUIT 2711 N. HASKELL <br /> 1DALLAS,TX 75204 <br /> 2" THREADED SEE NOTE PRODUCT LINE <br /> STEEL PIPE N #3 BELOW <br /> 2" FRP 318 " COPPER TO I — 2" UNION THEN NIPPLE <br /> FUNCTIONAL ELEMENT OF & 90' ELBOW <br /> (/ \) GASOLINE VENT SUBMERSIBLE /� I REVISION: DATE: <br /> \�/ SLOPE VENTS DOWN t/8 P2 FL NIPPLE 2"x2"x2" TEE <br /> TO TANKS (TYP. ALL LINES 4" x 2." DOUBLE II <br /> TAP BUSHING <br /> SUB PUMP END <br /> 2" DIA. MALE ADAPTER II <br /> II I I — <br /> 2" THREADED <br /> NOTE: STEEL PIPE �II <br /> VENT RISER DETAIL ALL DISPENSERS ARE TO BE POSITIONED WITH UNLEADED <br /> NOT TO SCALE ON THE LEFT OF THE "A" SIDE OF THE DISPENSER FACE. <br /> SIDE "A" OF DISPENSERS ARE TO ALWAYS FACE CLOSEST <br /> TO STORE FRONT. IF THE DISPENSERS ARE PERPENDICULAR d'� <br /> TO THE STOREFRONT, THE "A" SIDE WILL BE POSITIONED NOTES: <br /> TO THE RIGHT, LOOKING TOWARDS THE STORE. 1. ALL E TO T TO BE CONTAINED INSIDE RISER. <br /> 2 SLOPE TO TURBINE SIDE. N <br /> 3, ENVIRON FLEXIBLE ENTRY BOOTS (PART NO. FEB-6300) AT SIPHON PENETRATIONS, w <br /> 6 MPD'S 1-10,000 & 1-15,000 GAL. (1) 2 H.P. STP 6 WITH 3 X 2 RUBBER REDUCER BOOT (ENVIRON. N0. RRB-3030) ON SIPHON SIDE } <br /> _ STAGE a 'Y" FROM TANK TO FIRST BLENDER DISPENSER WITH t 1/2" & A 3 X 'L RUBBER TEST REDUCER (ENVIRON NO. RTR-3020) ON THE STP SIDE. cn <br /> FILL. VAPOR RECOVERY PRIMARY PRODUCT LINE, AND USE 1 1/2" PRIMARY PRODUCT UMP U <br /> �J TANK <br /> 2" GALV. STEEL VENT INTERSTIC1 2 LINE TO THE REST OF THE BLENDER DISPENSERS. <br /> . <br /> PIPE <br /> TO B[PAINTEDRT VENT R15ERS NOTE: FOR HIGH VOLUME LOCATIONS USE 2-15,000 GALLON TANKS Z" FG SIPHON DETAIL 0 <br /> "SOFT WHITE" STEEL 0 OR AS AN ALTERNATIVE, USE 3- 15,000 GALLON TANKS. NOT TO SCALE Q <br /> PLATE w 1 2 UMP NOTE:. > <br /> F 7. <br /> TANK MONITOR SIPHON TO BE USED FOR MANIFOLDING OF TWO REGULAR 10,000 GALLON TANKS AT LOCATIONS � <br /> -- 'h �I <br /> P WHERE THREE 10,000 GALLON TANKS ARE USED (1-10,000 PREMIUM & 2-10,000 REGULAR) w <br /> U <br /> 7" GAI V. 90 3" F <br /> 'I z Gz NSCOPF OE 44A z <br /> /8 2 ,� <br /> F <br /> F G ry of <br /> 2 F .y ti 11 P <br /> � MW. SLp1 1/2" <br /> _CIAMPS <br /> (TYP.) 2' FG O <br /> r <br /> UNLEADF_D SIL ,I �P g <br /> WRAP EXPOSED VENT RISER TANK I ` \ .•p SOF' FG O <br /> BELOW CONCRETE WITH 5 's <br /> 12" 3M CATHODIC PROTECTION _ FLEX CONNECTOR --- EQUIPMENT SCHEDULE �._ <br /> 1 TAPE NOTE: 1 2 PREMIUM z (TYP.) <br /> ) 2 FG ITEM DESCRIPTION MANUFACTURER, PART NO. FURN. BY <br /> PRIOR TO PAINTING, �� TANK i ?" � O FLE� GpNNECTOR TITEFLEX PART N0. 110165-242-0180 7-11 <br /> (2 ALL GALVANIZED METAL FG 1 _I12 X 18 M X MS <br /> Musr BE PREPPED 8 r�Nks rro& M�F.c O2 ENVIRON ISOLATION TUBE W/DONUT ENVIRON PART NO. FIT-3530, ITR-3020 7-11 <br /> NOTE, <br /> FREE- STANDING VENT DETAIL REVERSE TANKs IF LOCATED ON TOWARD F�cs<oP /� � �5`O� srORes°e 2" VAPOR VENT CAP (VAPOR VAC) OPW PART No. 523V-2253 7-11 <br /> NOT TO SCALE OPPOSITE SIDE OF ISLANDS _ <br /> NOTES: GEODUCT FLEXIBLE CONDUIT ENVIRON PART NO. ODP-4500-1 7-11 <br /> 1 . VENT RISER TO EXTEND A MINIMUM OF 12' ABOVE GRADE WHEN ' <br /> LOCATED IN REMOTE AREA. C� 4A GEOFLEX-D SUPPLY PIPING ENVIRON PART NO. CFP-2150 7-11 CENTRAL <br /> 2. ALL STEEL PIPE & CLAMPS ABOVE GRADE PAINTED "SOFT WHITE". PIPING SCHEMATIC SIX ISLAND MPD ' S DIVISION: <br /> PAINT FURNISHED BY 7-ELEVEN TO THE CONTRACTOR. 5 3" FIBERGLASS PIPE RED THREAD II OR AMERON G.C. <br /> NOTE: SEE SITE PLAN FOR PUMP AND VENT LOCATIONS — --- <br /> O 2" FIBERGLASS PIPE RED THREAD II OR AMERON C.C. <br /> 0 12" MANHOLE ASSEMBLY DPW PART NO. 104FG- 1200 7- 11 <br /> -- O8 4" X 4" X 3" X 2" EXTRACTOR ENVIRON PART NO. VEF-4432 7-11 <br /> O9 GEOTECH <br /> 6" THICK CONCRETE MATERIAL SEE SPEC. SECT. III 2.2 7-11 <br /> PAVING W/ #3'S © 18" O.C. <br /> BOTH WAYS. APPLY CONCRETE ELECTRICAL <br /> SEALANT PER SPECS.—� CONDUITS <br /> NOTE: <br /> SPECIFIED FILL ? ALL SUMPS TO BE WATER TESTED <br /> CD000 <br /> N <br /> VAPOR RECOVERY w <br /> LINE <br /> FIBERGLASS PIPING- OPRODUCT PIPING — NOTE: FOR VAPOR VAC INSTALLATION, <br /> 0" o STAGE II VAPOR RECOVERY LINE ISSUE Dare <br /> SECONDARY SHALL BE 2" FIBERGLASS PIPE WHEN <br /> PIPING THERE ARE TWO DISPENSERS OR LESS, <br /> AND 3" FIBERGLASS PIPE WHEN THERE <br /> ARE THREE DISPENSERS OR MORE. <br /> -PRIMARY STORE N0: <br /> 4° 4" PRODUCT LINE <br /> 6" 6" 6"-3/8" CK'D BY: <br /> PEAGRAVEL BEDDING <br /> APPROVED BY: <br /> 28" WIDE TRENCH GENERAL NO-FES 03/13/03 <br /> DATE ISSUED: <br /> 1 . PIPING TO BE TESTED UNDER PRESSURE DURING BACKFILL PROCEDURE DWS <br /> DRAWN BY: <br /> TO ASSURE NO BREACH IN SYSTEM - CHECK OFTEN DURING BACKFILL IL <br /> SECTION THRU PIPING TRENCH <br /> AND COMPACTION, <br /> NOT TO SCALE 2. STAGE II VAPOR RECOVERY PIPING TO BE PRESSURE TESTED FOR DECAY SHEET No. <br /> NOTE: IF CONDUIT OR WATER NEEDS TO CROSS TRENCH IT AND BLOCKAGE PRIOR TO BACKFILLING. <br /> SHOULD DO So PERPENDICULAR TO PRODUCT PIPE, 3. PIPING TO BE CHECKED FOR CONTINUOUS SLOPE BACK TO THE TANKS. (39 . OA <br /> OF 19 SHEETS <br />