Laserfiche WebLink
Dispenser Sump Aftical Information <br /> P on <br /> The UL-listed powder- Guide Specifications <br /> coated frame is fitted with <br /> a rigid 1-1/2" steel stabi- Short Form <br /> lizer bar and u-bolted flat The contractor shall provide the <br /> brackets for mounting Dispenser Sump, as manufac- <br /> boss shear valves. These lured byTotal Containment,Inc. <br /> improvements add to the <br /> structural integrity and The service access chamber <br /> safety features of Total shall be installed in accordance <br /> Containment" Dispenser with the manufacturer's pub- <br /> Sumps. lished instructions (DS1830). <br /> Pipe and Conduit Entries Long Form <br /> Dispenser Sumps are offered in cuffed and uncuffed models that accom- Design: The Dispenser Sump <br /> modate a variety of piping using a customized selection of reducers and shall consist of a containment <br /> bulkhead <br /> UL-listedmountingframe, <br /> bulkhead fittings respectively. Two applications are illustrated below. UL-listed mounting brackets, <br /> and UL-listed stabilizer bar.The <br /> Uncuffed Dispenser Sump with access chamber shall provide <br /> Enviroflex' DISPENSER SUMP <br /> Double-Wall Piping secondary containment of fuel <br /> The specialized bulkhead fitting leaks originating from the <br /> F81000 aboveground fuel dispenser unit <br /> (FB3650) seals Enviroflex piping to or fittings. located above or <br /> the wall of a dispenser sump,while 3/4" CONDUIT within the dispenser sump. <br /> the FB1000 bulkhead seals 3/4" ProductCompatibility:Allcom- <br /> conduit penetration. Test donuts F83650 TD5000 ponents of the Dispenser Sump <br /> (TD5000) are used to integrity test shall be compatible with the <br /> the secondary containment system. products) to be contained. <br /> } corrosion Resistance:All com- <br /> PP150 SP4000 ponents of the Dispenser Sump <br /> shall be made of non-corrosive <br /> materials, such that all metal <br /> fittings are isolated from corro- <br /> Cuffed Dispenser Sump with sion-causing elements. <br /> Fiberglass Double-Wall Piping DISPENSER SUMP Structural Integrity: The Dis- <br /> The CS3903 reducer with a 3" in- penser Sump shall provide <br /> sert (CS3930) transitions from the TR7503 strength sufficient enough to <br /> 5" cuff of a dispenser sump to the keep out surrounding backfill <br /> double-wall (2" contained within 3/4" CONDUIT material. <br /> 3")FRP pipe. The air valve stem on Monitoring Capability:The de- <br /> the reducer is used to air test the 3" FRP PIPE sign of the Dispenser Sump shall <br /> be capable of being fitted with a <br /> secondary containment system. leak detection system. <br /> 2" FRP PIPE <br /> CS3903 W/CS3930 <br /> Contact your local authorized petroleum distributor or Total Containment,Inc.for Distributed by: <br /> additional information on TCI's environmental protection products designed for <br /> a total systems approach to secondary containment: <br /> EnviroflexT Sump/Risers Bulkhead Fittings <br /> Double-Wall Tanks Dispenser Sumps/Pans Pipe Jacket® <br /> TOTAL <br /> CONTAINMENT <br /> INC <br /> IIIIIII <br /> 306 Commerce Drive • Exton, PA 19341 • 215-524-9274 • FAX 215-524-7530 <br /> Printed in U.S.A on Recycled Paper <br /> Designs and specifications are subject to changes without notice. REV0693T <br /> ©TO 1993.U.S.&Worldwide Patents <br />