My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LILLIAN
>
403
>
2800 - Aboveground Petroleum Storage Program
>
PR0540801
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2019 9:29:22 AM
Creation date
8/20/2019 2:00:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0540801
PE
2832
FACILITY_ID
FA0009058
FACILITY_NAME
VAN DE POL ENT INC FACILITY # 107
STREET_NUMBER
403
Direction
N
STREET_NAME
LILLIAN
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
14337012
CURRENT_STATUS
01
SITE_LOCATION
403 N LILLIAN AVE
P_DISTRICT
002
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10 November 2016 AdvancedG <br /> AGE Project No . 16 - 3876 E n v i rc) n m e n t a l <br /> Page 19 of 25 <br /> 4 . 2 . 5 . Partiall Buried and Bunkered Storage Tanks - 40 CFR 112 . 8 ( c) ( 5 ) <br /> This section is not applicable as no partially buried or bunkered storage tanks are at this <br /> facility . <br /> 4 . 2 . 6 . Inspect ons and Tests - 40 CFR 112 . 8 ( c) (6 ) <br /> Facility perso nel conduct weekly , undocumented , visual inspections of ASTs in <br /> accordance with Section 3 . 7 . of this SPCCP . Leaks from tank seams , gaskets , rivets , and <br /> bolts are promptly corrected . Monthly and annual inspections are documented utilizing <br /> the inspection form included in Appendix B . Records of inspections and tests are signed <br /> by the inspector and kept at the facility for at least three years , unless otherwise specified . <br /> The scope and schedule of certified inspections and tests performed on the facility ' s ASTs <br /> are specified in STI Standard SP - 001 . The external inspection may include visual <br /> observations , ultrasonic testing of the shell , as specified in the standard , or if <br /> recommended by the certified tank inspector to assess the integrity of the tank for <br /> continued oil torage , with actual inspection type depending on facility management . <br /> Currently facil ty management has deemed that visual inspection are sufficient as it <br /> pertains to ASTs at this facility . Table 8 summarizes inspections and tests performed on <br /> ASTs . RecordO of certified tank inspections are kept at the facility for at least three years . <br /> Shell test corn arison records are retained for the life of the tanks . <br /> 4 . 2 . 7 . Heating Coils - 40 CFR 112 . 8 ( c) ( 7 ) <br /> This section is not applicable since there are no ASTs equipped with heating coils at this <br /> facility . <br /> 4 . 2 . 8 . Overfill Prevention Systems - 40 CFR 112 . 8 ( c) ( 8) <br /> All ASTs are cbserved utilizing a manual method in the prevention of overfill ( i . e . gauge <br /> stick) . Facility tanker trailer loading and unloading operations are performed solely by <br /> facility person el trained in proper discharge prevention procedures . Venting capacity is <br /> suitable for fill nd withdrawal rates . <br /> The emergen y shut off switch is clearly marked and visible with appropriate location <br /> signs . <br /> Facility personnel are present throughout the filling operations to monitor thep roduct level <br /> in the tanks . <br />
The URL can be used to link to this page
Your browser does not support the video tag.