Laserfiche WebLink
RESULTS <br /> See Table 1 for results influent/effluent monitoring of the <br /> system and Table 2 for the results of REMOX operation <br /> CONCLUSIONS <br /> The VOC emissions during current REMOX operations for the period <br /> 08/1/94, 09/02/94 have not exceeded the 52 lb/day limit No DCE, <br /> TCE or PCE has been detected in the samples <br /> The average Natural Gas usage to 7/20/92 was 2 2 cfm, or 3168 cf <br /> per operational day, following the exchange of the unit on <br /> 8/18/92 the average Natural Gas usage to 11/04/95 was 5 28 cfm <br /> or 7607 cfd Since the replacement of the burner on 11/05/93 , the <br /> average natural gas usage is 3 7 cfm or 5304 cfd which is below <br /> the permit limit of 17, 280 cfd <br /> As of September 2 , 1994 , A total of 73897 pounds of gasoline <br /> have been destroyed during operation of the vapor recovery <br /> system <br /> The system was destroying, as of September 2 , 1994 , 2 13 pounds <br /> per day of hydrocarbon <br /> RoVS er <br /> Gegist <br /> CC <br /> Richard Smith <br /> San Joaquin Valley Unified Air Pollution Control District <br /> 4230 Kiernan Ave #130 <br /> Modesto, CA 95356 <br /> (209) 545-7000 <br /> Mary F Meays <br /> Public Health Services <br /> P O Box 2009 <br /> Stockton, California 95201 <br /> page 6 of R603 , 09/16/94 <br />