INSTALL 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
INSTALL 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2019 8:33:37 AM
Creation date
8/21/2019 3:51:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2005
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Note: Enhanced Leak Detection (ELD) must be performed prior to the final inspection. A <br />separate permit application is required to install ELD. <br />2. TO BE SUBMITTED PRIOR TO THE FINAL INSPECTION: <br />❑ Complete to scale As -Built Plans <br />❑ Complete Monitoring and Response Plan <br />❑ UPCF Underground Storage Tanks - Installation Certificate of Compliance (one form per <br />tank) <br />❑ Completed Underground Storage Tank Certification of Financial Responsibility form along <br />with any required attachments <br />❑ Passing Line Leak Detector Test Results <br />❑ Passing Line Tightness Test Results (Required if the UST system does not satisfy the <br />California Code of Regulations 2636(g) for automatic pump shut-off.) <br />❑ Passing Enhanced Leak Detection Results <br />D. INSPECTIONS: <br />Note: A representative from the San Joaquin County Environmental Health Department <br />must witness all activities described below. <br />❑ Tank holiday test (for fiberglass -coated steel tanks) performed prior to installation in <br />excavation <br />❑ Inspection of tank vacuum gauge (if applicable) prior to placement in excavation <br />❑ Tank soap test (for fiberglass tanks) performed prior to installation in excavation <br />❑ Verification of tank set and anchorage in excavation <br />❑ Primary piping including product piping, vapor recovery and vent line piping soap and <br />pressure test <br />❑ Secondary piping including product piping, vapor recovery and vent line piping soap and <br />pressure test <br />❑ 24 -Hour secondary containment lake test on sumps and under -dispenser containment <br />❑ Visual inspection of piping to ensure proper slope prior to covering <br />❑ Overfill performance test <br />❑ Prior to receiving fuel, a complete functional test of tank and piping monitoring system(s) <br />including overfill prevention <br />❑ Final inspection and demonstration of automatic shut down (if applicable). <br />-5- <br />
The URL can be used to link to this page
Your browser does not support the video tag.