My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
INSTALL 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2019 8:33:37 AM
Creation date
8/21/2019 3:51:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2005
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping information continued - <br />Check <br />Code <br />Section <br />Box <br />Code <br />Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br />Section <br />Manufacturer OPW Model Z l o o S a -(t. & F—S <br />z5z9o.1(c)(l) <br />Piping compatible with material intended to be stored. <br />® <br />25290.2(c)(1) <br />Choose One of the following methods: <br />23 CCR <br />Design and construction of piping approved by independent testing organization (e.g. UL). <br />2631 <br />triggering an audible visual alarm <br />®Piping, <br />23 CCR <br />including vent lines, sloped toward tanks with minimum 1/4 inch sloe per 1 foot of run. <br />HSC <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an audible <br />® <br />2529o.2C&G) <br />Vapor recovery, fill riser, and vent line piping are secondarily contained. <br />G. OVERSPILL/ OVERFILL PREVENTION: <br />Check <br />Box <br />Code <br />Section <br />® <br />23 CCR <br />Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br />2635(b) <br />Manufacturer OPW Model Z l o o S a -(t. & F—S <br />Approved overfill prevention device provided at each tank fill location. <br />® <br />23 CCR <br />Choose One of the following methods: <br />2636(6) <br />❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br />triggering an audible visual alarm <br />® <br />23 CCR <br />❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br />2635(ax2) <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an audible <br />23 CCR <br />alarm at least five minutes before the tank overfills <br />❑ <br />2635(bx2) <br />Tie -downs, when used, constructed of non -corrosive material or coated steel. <br />D( Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br />capacity. <br />❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br />tank are exposed to product due to overfilling. <br />Manufacturer GFW Model I SO - v iz <br />H. CORROSION PROTECTION: <br />Check <br />Box <br />Code <br />Section <br />D� Fiberglass reinforced plastic (FRP) <br />Piping corrosion protection: L1 Steel with cathodic protection or impressed current <br />® <br />23 CCR <br />Li Steel isolated from contact with backfill <br />2636(6) <br />(( FRP or equivalent non-metallic exterior coatings or coverings <br />® <br />23 CCR <br />Tank corrosion protection: ❑ Sacrificial Anode <br />2635(ax2) <br />❑ Steel tank with field installed cathodic protection or impressed <br />current <br />❑ <br />N (A <br />Tie -downs, when used, constructed of non -corrosive material or coated steel. <br />-7- <br />
The URL can be used to link to this page
Your browser does not support the video tag.