Laserfiche WebLink
f / <br />HUNTER ENVIRONMENTAL SERVICES, LNC. <br />597 CENTER AVENUE, SUITE 350 <br />MARTINEZ, CA 94553 <br />1-800-321-3637 <br />FINAL TEST RESULTS <br />TEST DATE: 3/7/89 <br />CUSTOMER: SHELL LOCATION/IDENTIFICATION NO.: 204-7524-2804 <br />ADDRESS: 4315 WATERLOO RD. <br />STOCKTON, CA <br />TEST RESULTS SUMMARY <br />LEAK LOKATOR RESULTS <br />SYSTEM TANK SIZE WATER LEVEL ALR RECOMMEN- <br />NO PRODUCT GALLONS DIA/MATL INCHES INCHES GPH CONCLUSION DATIONS <br />1 SUPER <br />8,000 <br />95 "/ST <br />0 <br />160 <br />-.030 <br />TIGHT <br />2 U/L#1 <br />5,000 <br />95"/ST <br />0 <br />155 <br />-.034 <br />TIGHT <br />3 U/L#2 <br />5,000 <br />95"/ST <br />0 <br />155 <br />-.034 <br />TIGHT <br />4 REC <br />6,250 <br />95"/ST <br />0 <br />165 <br />-.023 <br />TIGHT <br />NOTE: No drop tube in U/L tank without pump. <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />SYSTEM TYPE OF PUMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br />NO PRODUCT REMOTE SUCTION APPLIED HELD HELD LOSS CC's LOSS GPH /RESULT <br />1 <br />SUPER RJ <br />50 <br />50 <br />15M <br />2 <br />U/L #1&2 RJ <br />50 <br />50 <br />15M <br />3 <br />REC RJ <br />50 <br />50 <br />15M <br />NOTE: <br />On suction systems, <br />NEVER put <br />more than 15 <br />psi on any pump system. <br />DETAIL OF TEST RESULTS <br />PASS <br />PASS <br />PASS <br />*LEVEL - Inches from Tank Bottom to Test Level <br />AIR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons <br />Per Hour. <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness. <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL <br />SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated <br />as tight at full system meet the criterion established by the National Fire Protection <br />Association Pamphlet 329 for Precision Testing. <br />Test Conducted By: Test Van No. 4 <br />Team Manager: PAT WHEELER <br />Tank Testing Specialist: J.R. EVANS <br />Certification By: Pat Wheeler, Operations Manager <br />A:SHELL2804.RES CERT I + <br />A <br />TEST <br />TIME <br />TEMPERATURE <br />ABSOLUTE CHECK <br />SYSTEM <br />TEST <br />LEVEL <br />CLOCK <br />DURATION <br />LEAK <br />RATE <br />COMPENSATION <br />LEAK RATE TEST <br />NO <br />PRODUCT <br />NO <br />(IN.) <br />START <br />(HR -MIN) <br />CC/DIV <br />CC/MIN <br />DELTA OF <br />CC/MIN <br />CC/MIN <br />GPH Y/N <br />1 <br />SUPER <br />1 <br />160 <br />2:15 <br />1-0 <br />-4.152 <br />-1.490 <br />-.010 <br />-3.431 <br />-1.441 <br />-.030 <br />N <br />2 <br />U/L#1 <br />1 <br />155 <br />11:25 <br />1-0 <br />-3.045 <br />-4.496 <br />-.008 <br />-1.665 <br />-2.207 <br />-.034 <br />N <br />3 <br />U/L#2 <br />1 <br />155 <br />11:25 <br />1-0 <br />-3.045 <br />-4.496 <br />-.003 <br />-.624 <br />-2.207 <br />-.034 <br />N <br />4 <br />REC <br />1 <br />165 <br />10:25 <br />1-0 <br />+3.428 <br />+1.371 <br />+.011 <br />+2.862 <br />-1.491 <br />-.023 <br />N <br />*LEVEL - Inches from Tank Bottom to Test Level <br />AIR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons <br />Per Hour. <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness. <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL <br />SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated <br />as tight at full system meet the criterion established by the National Fire Protection <br />Association Pamphlet 329 for Precision Testing. <br />Test Conducted By: Test Van No. 4 <br />Team Manager: PAT WHEELER <br />Tank Testing Specialist: J.R. EVANS <br />Certification By: Pat Wheeler, Operations Manager <br />A:SHELL2804.RES CERT I + <br />A <br />